The service distribution needs to have a disconnect from the utility supply. Most homes use a combination distribution panel. If the home owner wants to have a load center installed then there has to be a fused disconnect ahead of the panel. The less costly of the two options is the combination panel. Labour costs drive the load center, main service switch option much higher because there are more materials to assemble.

User Avatar

Wiki User

12y ago

What else can I help you with?

Continue Learning about Electrical Engineering

How do you connect 200amp from main panel to sub panel to the lug of the min panel to lug of sub panel?

Not exactly sure what your question is and you need to make sure you are in compliance with electrical code for your jurisdiction. But, generally speaking you install a large breaker (let's say 100A 2 pole breaker to power the sub panel) just as you would install any other breaker in the presently used (hot) panel, and the proper sized cable then goes from old to new and terminates on the main lugs of the new panel. Ground and neutral are usually isolated from each other in the sub panel but depends on other factors as to location of the sub panel, etc.


How do you install 220 receptacle with white black and bare wires?

Assuming the wires are the correct gauge for application and breaker you use black and white wires as hot. Put red electrical tape on each end of white wire and connect red and black to the breaker output and bare wire to ground lug in panel. At receptacle connect black and red to hot contacts and bare wire to ground lug.


How do you connect 240V electric water heater?

On a 120/240 volt distribution system the ground wire is terminated at the point where the service neutral terminated in the distribution panel. It is usually a double lug the neutral wire connecting into one hole and the ground wire connecting into the other hole. Through this lug assembly there is a machine screw that is inserted through the lug assembly and it screws into the metallic enclosure of the distribution panel. This action bonds the metal enclosure, neutral wire and ground wire bringing the point to a common potential of zero.


Why is the neutral point grounded on a transformer?

The secondary side (output) of a three phase transformer develops a "separately derived system". That is why you do notsupply a neutral to a three phase transformer. It develops its own reference to ground by being bonded to the transformer casing and to a substantial earth ground, such as a ground rod. The XO tap on a transformer provides the neutral to the secondary line. It will have a double wire lug. The neutral wire going to the panel being supplied goes under one lug and the same size wire is to go to the ground lug on the transformer chassis The ground lug is also a double with the other lug to be wired to the earth ground.


CAN YOU CUT A 2 HOLE LUG DOWN TO 1 HOLE?

You can, but you will destroy the lugs certification if you do. Without the certification on a field modified piece of equipment you stand the chance of getting a rejection if the project is ever inspected by an electrical inspector.Just use the double barrel lug until you can get a proper single barrel lug and then change it out. Keep in mind the cost of a double barrel lug is about four times that of a single barrelled lug.

Related Questions

I have a Transformer 480 primary 208 secondary feeding 1 200amp mb 42 space panel I need to feed a subpanel 6 ft away I'm thinkin feed through lug at top of bus or at feed through MB suggestions?

The sub-panel need to be fed from the main panel, by way of a circuit breaker connected to one of the breaker locations. Or if your sub-panel has a main breaker installed you can feed from the main panel with a sub-feed lug kit. This looks like a breaker, but is only a point where you can branch off the sub panel.


How do you connect 200amp from main panel to sub panel to the lug of the min panel to lug of sub panel?

Not exactly sure what your question is and you need to make sure you are in compliance with electrical code for your jurisdiction. But, generally speaking you install a large breaker (let's say 100A 2 pole breaker to power the sub panel) just as you would install any other breaker in the presently used (hot) panel, and the proper sized cable then goes from old to new and terminates on the main lugs of the new panel. Ground and neutral are usually isolated from each other in the sub panel but depends on other factors as to location of the sub panel, etc.


In a typical home electrical panel installation the main ground wire is connected directly from a ground rod driven into ground to the 1 case of the panel or 2 main breaker switch or 3 l?

The main ground wire in a typical home electrical panel installation is usually connected directly from a ground rod driven into the ground to the case of the panel. This helps to ensure that the panel is properly grounded to prevent electrical shocks and provide a safe path for electricity to follow in case of a fault.


What is the purpose of a double lug breaker and how does it function in an electrical circuit?

A double lug breaker is used to connect two separate electrical circuits to a single breaker. It functions by allowing both circuits to be controlled by the same breaker, providing a convenient way to manage multiple circuits with limited space in an electrical panel.


What are the key features and specifications of the Square D 125 amp panel?

The Square D 125 amp panel is a type of electrical panel that can handle up to 125 amps of electricity. It typically has a main breaker or main lug, along with multiple circuit breaker slots for individual circuits. The panel is designed to safely distribute electricity throughout a building, with features such as overload protection and grounding capabilities. It is important to consult the manufacturer's specifications for specific details on the panel's dimensions, materials, and installation requirements.


Can you connect Two wires to one main lug in a panel board?

No, you should not connect two wires to one lug in a panel board. Each lug is designed to accommodate only one wire in order to ensure proper connections and to prevent overheating. If you need to connect multiple wires, you should use a wire nut or a junction box to splice the wires together before connecting to the lug.


What are the key features and specifications of the Siemens 125 amp panel?

The Siemens 125 amp panel is a electrical distribution panel that can handle up to 125 amps of electricity. It typically has a main breaker or main lug, multiple circuit breakers for individual circuits, and is designed for residential or light commercial use. It is important to consult the specific model's specifications for exact details on features and dimensions.


Which terminal on a 15 amp household breaker does the hot wire feed into and which one does it come out?

On a 15 amp household breaker there is no terminal on the in feed of the breaker. The breaker either plugs into the distribution panel's bus bar or it bolts to the distribution's bus bars. The feed conductor connects to the load side of the breaker at its terminal lug.


Can a200 amp breaker lug handle a?

Handle a "What"?


What is included in the sub feed lug kit?

The sub feed lug kit typically includes lugs, screws, and other necessary components for connecting the sub feed to the main electrical panel.


How do you hook up a sub panel box for 220 and 110?

You bring in the two phases from the main panel plus a neutral wire and a ground wire. you land the two hot wires on the two hot lugs at the top of the panel and the neutral wire to the neutral buss.and the ground wire to the ground buss strip. when you take power from a single breaker and the neutral, its 110. when you pull power from both hots on a 2 pole breaker with no neutral, its 220 If you dont have a set of lugs at the top, you can feed into a two pole breaker mounted in the panel.Make sure your panel has a two phase lug mount. to check to make sure, with the breaker mounted and no power wires connected and all the breakers except your new 2 pole breaker off. use an ohm meter to make sure that there is no conductivity between the two pole breaker terminals. if there is conductivity, thre panel is not suitable to feed with 220, its a 110 panel, with only one phase back board.


Can you tie the neutral wire on a sub feed to another panel to the main neutral lug?

No, the neutral wires from different panels should not be tied together at the main neutral lug. Each panel should have its own separate neutral connection to the main service panel to ensure proper grounding and to prevent potential hazards such as ground faults. Mixing neutral wiring from different panels can cause electrical imbalances and safety issues.