140 amp
What is current carrying capacity of 50x8 mm copper flatbusbar.
It depends on the the number of cores, type of insulation, whether armoured or unarmoured, and method of installation. So, there is no simple answer. You must determine the current-carrying capacity from the Tables provided in BS 7671:2008 Requirements for Electrical Installations, or the equivalent used in your country.
70mm 4core copper cable
what is the maximum load current of 3X95+50 cable cu, xlpe
A #10 copper conductor with an insulation rating of 90 degrees C is rated at 30 amps. The only time that a breaker larger that the load maximum capacity can used is in motor connections. A breaker can be used sized at 250% of the motor's full load amperage. In this case a 50 amp breaker can be used on a #10 conductor if the motor's full load amps falls within the amperage's of 20 - 22 amps.
What is current carrying capacity of 50x8 mm copper flatbusbar.
It depends on the the number of cores, type of insulation, whether armoured or unarmoured, and method of installation. So, there is no simple answer. You must determine the current-carrying capacity from the Tables provided in BS 7671:2008 Requirements for Electrical Installations, or the equivalent used in your country.
300ams
The current carrying capacity of a 10 sqmm copper cable is typically around 70-100 amps, depending on factors such as insulation type, installation method, and ambient temperature. For aluminum cables, the capacity is generally lower, around 50-80 amps. It's essential to refer to specific standards and local regulations for precise values and to ensure safe electrical installation. Always consider derating factors for specific conditions.
70mm 4core copper cable
50 sq.mm of aluminium and 25 to 35 sq.mm of copper
There's no such word as "'Ampacity". The current carrying capacity of 50mm cable is around 300A continuous or 365amps @ 60% duty cycle. It's generally used for engine starter circuits or high current welders.Answer'Ampacity' is a North American term for the 'current-carrying capacity' of a cable. It is not used in most other English-speaking countries.
The nearest AWG wire size to 50 sq. mm is 1/0. A 1/0 aluminium conductor with an insulation factor of 75 or 90 degrees C is rated at 180 and 205 amps respectively.
what is the maximum load current of 3X95+50 cable cu, xlpe
just apply the formula :-p=v*i*cos(angle);now you have the power rating,load so in turn power factor so you can easily calculate the value of current.with the help of current you can chose the cable available in the market either the aluminum or copper wiresatendra.svnit@gmail.com
No, we are not carrying 50 bananas.
The current carrying capacity of a 10sqmm copper conductor depends on factors such as ambient temperature, insulation type, installation method, and conductor grouping. As a general guideline, for typical installation conditions, a 10sqmm copper conductor can carry around 40-50 amps of current. It is important to consult with local electrical codes and standards for precise values.