disandvantage:-the wheatstone bridge is not applicable for high resistances advantage:-1)it shows a null measurement(i.e.-potential difference across the end points of the bridge is zero) 2)since it is an arrangement of 4 resistors ...it is useful to find one of them in terms of other 3
Kelvin Bridge: This Bridge is a modified version of Wheatstone Bridge and provides greatly increased accuracy in the measurement of low value resistances, generally below 1 ohm.
A Carey-foster's bridge is a modified version of the meter bridge (wheatstone bridge or potentiometer). It can be used to find out the average resistance per unit length of the meter bridge wire and hence find out the unknown resistance. It is more accurate and more sensitive than a meter bridge.
The biggest advantage of the Wheatstone bridge is the accuracy of the resistance readings. I had two cables short out underground, by knowing the resistance of the wires per foot I located the fault within 3 feet of where the two wires touched each other.
Because by increasing the load resistance, the total circuit resistance is reduced. This means with less resistance, there is more current drawn from the source. Doubling the size of a load resistor increases the load current.
The wheatstone bridge is an instrument used to measure electrical resistance by means of balancing a bridge circuit. The bridge circuit contains two legs, one of which contains the unknown resistance. Variations in wheatstone bridge can be employed to measure inductance, capacitance, and impedance also.
The wheatstone bridge is an instrument used to measure electrical resistance by means of balancing a bridge circuit. The bridge circuit contains two legs, one of which contains the unknown resistance. Variations in wheatstone bridge can be employed to measure inductance, capacitance, and impedance also.
WHEATSTONE BRIDGE : A wheatstone bridge is used to measure an unknown electrical resistance by balancing two legs of a bridge circuit, one leg of which includes the unknown compound.Its operation is similar to the original potentiometer. METER BRIDGE : A uniform resistance wire 1 meter in length, mounted above a scale marked in millimeters, with terminals added to make the device usable as either part of a wheatstone bridge or of a potentiometer.
You use a transducer in a wheatstone bridge. The wheatstone bridge allows you to find an unknown resistance.
An ohmmeter is a device used to measure the resistance of a component or circuit by passing a current through it and measuring the voltage drop. In contrast, a Wheatstone's bridge is a circuit used to measure an unknown resistance by balancing it against known resistances in a bridge configuration, without passing a current through the unknown resistor. Wheatstone's bridge is more accurate for precise resistance measurements compared to an ohmmeter.
just to find out our given unknown resistance value or to put it another way, To find the value of the unknown resistor attached.
with a wheatstone bridge
kelvin's bridge is the modified version of wheatstone bridge and used to measure resistance values less than 1 ohm.
A meter bridge is used to measure an unknown electrical resistance by comparing it with a known resistance. It works on the principle of Wheatstone bridge. By balancing the bridge circuit, the value of the unknown resistance can be calculated accurately.
with a wheatstone bridge
At a balanced condition the voltmeter connected across the wheatstone bridge will be zero.
It is an circuit that is used to find the value of the resistances. The main principle behind it is the balancing an circuit by means of varying an resistance on connected to an arm of the circuit.When the resistance become equal to the variable resistance no current flows thus we can find the value of the resistance.