Yes. If they are single wires they need to be in a conduit.

User Avatar

Wiki User

13y ago

What else can I help you with?

Continue Learning about Electrical Engineering

Which one is cheaper PVC conduit or emt conduit?

PVC is cheaper but is used differently. PVC is usually baried in ground and emt usually runs exposed. You can use PVC exposed if it is schedule 80 gray PVC electrical conduit. Schedule 40 is for under ground


Do you have to run wiring in conduit if its in the ground?

Wire in conduit for underground feeders has to have an insulationrating for wet and damp locations. In the marketplace there is also wiring thathas an insulation rating for direct burial that does not need to be installed into conduit.


What diameter mast do you need for 200 amp service?

2 inch Rigid or IMC conduit if it's on a structure. 2 inch schedule 80 PVC conduit if it's on a wood pole.


Can you run conduit on a chain link fence?

Yes, you can run conduit on a chain link fence, but there are some considerations to keep in mind. Ensure that the conduit is securely fastened to the fence to prevent movement and damage, while also complying with local electrical codes. Additionally, consider the potential impact on the fence's structural integrity and the need for proper weatherproofing if the conduit will carry electrical wiring.


What are the methods of producing bends and sets in conduit materials?

Bends and sets in conduit materials can be produced using several methods, including manual bending with hand tools like conduit benders, which apply leverage to create the desired angle. Mechanical benders and hydraulic benders are also commonly used for larger or thicker conduit, providing more consistent and precise bends. Additionally, heat bending involves applying heat to thermoplastic conduits to make them pliable before shaping. Lastly, pre-fabricated fittings can be used to create bends without the need for bending the conduit itself.

Related Questions

I am installing a 200 amp service in my home. i have moved the panel to the middle of the house i want to take the triplex through the crawl space to the panel do i need to run it through anything?

Yikes. No triplex is for connections to the mast head from the power pole. You should rethink this panel move. Check with someone that knows the (NEC in the US) code. I am in Canada and our CEC states that the service entrance and meter base has to remain on the outside of the building and that no part of the service from the meter base to the first over current device (main breaker) shall be run inside the building. This is for safety reasons as the wires from the meter base to the main breaker are only protected by the primary fuse. Have you ever seen news clips of a house fire and the service drop is on the ground sparking away like welding is being done. This is because the primary fuse has not blown and disconnected the power. What you are proposing to do is bring this into your house. Triplex is an free air rated cable and is not to be put into conduit. Woodman66 thanks for the quick reply Please check disscussion area as i am not familiar with replying on wiki Quick_68 - AS it turns out i read up a lot more about what i can run into the house. Because i am installing a disconnect switch outside the house by the meter i can have the panel box inside the middle of the house. This disconnect switch is nothing more than a single breaker box with a 200 amp breaker that i got from home depot for 130 or so dollars as a unit. As for the wire i need to run into the house from the meter to the panel inside, there are only specific types of triplex that can be used. One that would not work is Triplex URD also known as "sweetbriar." The reason for this is because the insulation is not fire rated for in house use, or under house"above ground" run no matter if its in conduit or not. Another 4/0 4/0 2/0 cable would need to be ran that has qualified insulation. Just thought id add that side note incase someone else came across this question. Glad you got things straightened out. Better to be safe than sorry. Good luck on your project.


Do you need a conduit engine on your computer?

No you do not need one unless you need Conduit powered apps. A Conduit Engine is the module of Conduit Open that allows users to add apps directly to their browser without a community toolbar. It offers you an important new distribution option for your Conduit-powered offerings.


Which one is cheaper PVC conduit or emt conduit?

PVC is cheaper but is used differently. PVC is usually baried in ground and emt usually runs exposed. You can use PVC exposed if it is schedule 80 gray PVC electrical conduit. Schedule 40 is for under ground


How to bend conduit effectively and accurately?

To bend conduit effectively and accurately, you need to measure and mark the conduit accurately, use a conduit bender tool, align the conduit properly in the bender, and apply gradual pressure to create the desired bend angle. Practice and experience will help you improve your bending skills.


Do you have to run wiring in conduit if its in the ground?

Wire in conduit for underground feeders has to have an insulationrating for wet and damp locations. In the marketplace there is also wiring thathas an insulation rating for direct burial that does not need to be installed into conduit.


Which industry uses conduit clamps?

Conduit clamps are used for jobs in which one deals primarily with pipes. A plumber, for example might have a need for conduit clamps, or a construction worker who is building a hose. Home Depot always has a large selection of conduit clamps available.


When should you use conduit bends?

You should use conduit bends when you want to bend a pipe to any angle, either 90 or 30 degree angles. To achieve this, you need to master the maths formulas for bending conduit.


Need a 30 amp 220 overhead drop to a hen house what wire should you use?

To overcome any voltage drop from distance to the hen house use a triplex #8. Use the neutral messenger with wedge grips on either end of the cable to hold the conductors and the two insulated wires to carry the voltage.


What size drill bit do you need for a piece of conduit?

Depends on the diameter of the conduit. Try for 1/4" larger diameter drill bit.


What is another name for thin wall conduit?

There are many types of conduit used for the containment of electrical wires. PVC is a non-metallic option. If you need something that provides mechanical protection, EMT is a steel conduit with a thin wall. Need even more mechanical protection, you can use rigid conduit. It comes in steel or aluminum, and must be threaded together.


How deep does conduit need to be buried to ensure proper installation and safety?

Conduit should be buried at a depth of at least 18 inches to ensure proper installation and safety.


How can I run conduit through an exterior wall?

To run conduit through an exterior wall, you will need to carefully measure and mark the location where you want the conduit to pass through. Then, use a drill with a hole saw attachment to create a hole in the wall. Next, insert the conduit through the hole and secure it in place using appropriate fasteners. Finally, seal around the conduit with caulk or weatherproofing material to prevent water infiltration.