Home owner big job. In the trade this is called a service change or upgrade. It is a complicated job in as much as you have to know wire sizes, ampacity of wires and proper electrical workmanship. Such a project should be left to a licensed electrical contractor to take out the proper permits and call for proper inspections. By taking this route it will leave you confident that if any mishaps happen to the installation down the road your insurance company will be behind you 100%. <><><>
As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.
Before you do any work yourself,
on electrical circuits, equipment or appliances,
always use a test meter to ensure the circuit is, in fact, de-energized.
IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOB
SAFELY AND COMPETENTLY
REFER THIS WORK TO QUALIFIED PROFESSIONALS.
1. ADD SOLAR PANEL COLLECTORS 2. ADD MORE STATION BATTERIES 3. REPLACE CHARGER OR ADD CHARGERS ACCORDING TO UPGRADE.
a ten-wrap amperage multiplier is used with a (n)
Wire is sized by the amperage that it will carry. 5 kW is 5000 watts. The equation to find watts is W = Amps x Volts. The equation to find amps is Amps = Watts/Volts. As you can see a voltage is needed to calculate the amperage. Once the amperage is stated, the wire size can be given for that particular amperage.
There are zero watts in 220 volts. Watts are the product of amps x volts. To receive an answer, the amperage of the device has to be stated. This amperage multiplied by the stated voltage will give you the wattage of a device.
The formula for amps is I = W/E. Amps = 40/240 = .17 primary amperage. For the secondary amperage I = W/E. Amps = 40/24 = 1.7 amps.
The only way you can upgrade your 2002 Mitsubishi Eclipse alternator is to change the alternator. Larger amperage alternators are available.
1. ADD SOLAR PANEL COLLECTORS 2. ADD MORE STATION BATTERIES 3. REPLACE CHARGER OR ADD CHARGERS ACCORDING TO UPGRADE.
Amperage is electric current of flow.
I doubt if the 125 amp breaker will fit into a 100 amp box. This is due to the rating of the box only being rated at 100 amps. If this exchange could be made then the service conductors feeding the box must be upgraded to take the 125 amperage that the breaker will allow on the conductor.
No, it is not safe or recommended to connect a 200 amp service to a 125 amp panel. The panel must be rated to match the amperage of the service to avoid overloading the panel and potential fire hazards. It is important to upgrade the panel to match the service amperage.
It is ok to use a fuse with a higher amperage rating and not ok to use a fuse with a smaller amperage rating why?
Upgrade is a noun (an upgrade) and a verb (to upgrade).
This doesn't make sense, "current" is "amperage" so the higher the voltage the lower the amperage, and the lower the voltage the higher the amperage.
in the upgrade room is the room to upgrade
There is no proper amperage...no such thing as amperage, its called current... measured in amps...
Wire size is based on the amperage drawn. To find the amperage, the voltage must be stated. Use this formula to find the amperage. I = W/E. Amps = Watts/ Volts. Once you have the amperage, restate your question using the new found amperage or state the voltage that supplies the lights.
An amperage is the electric current's strength carried by a conductor or machine generated as measured in amperes.