Most of the commercial and Industrial installations have large electrical loads which are severely inductive in nature, such as motors, large machines, air conditioners, drivers etc. Which results in a severely lagging power factor. This means loss and wastage
of energy and heavy penalties by electricity boards. In case of fixed loads this can be taken care by manual switching of capacitors.

However in case of rapidly varying and scattered loads it becomes difficult to maintain a high power factor by manually switching on/off the capacitors in proportion to variation of load within an installation. This drawback is overcome by using an APFC panel (Automatic Power Factor Correction Panel) which not only maintains a high power factor but also eliminates the eliminates the need for constant manual intervention.

The ratio of Active Power to Apparent Power is called Power Factor (PC) :


Power Factor = Active Power/ Apparent Power = KW/KVA

If you want to know more about PFC panels please visit www.powerfactorcorrector.com or email me on info@urjaghar.com.

User Avatar

Wiki User

15y ago

What else can I help you with?

Related Questions

What is the purpose of power factor correction?

Power factor correction is a process that has to do with managing the essential traits of electric loads that are used to create a power factor of less than one.


Papers on automatic power factor controller?

automatic power factor controller


What is PFI panel?

Power Factor Improvement Panel. It controls power factor


What is an automatic power factor control panel?

somewhere near where power comes into a building there is a phase angle or power factor meter automatic control will add capacitor banks until the phase angle is 0 when fluorescent lamps used transformer ballasts there could be lagging power factor lightly loaded motors do this too the power company charges you more if you have a load that is not near unity


When induction motors is used for power factor correction what is called?

I'm not sure I've ever seen an induction motor used to correct power factor; it is usually the induction motors that are causing the poor power factor. "Power factor correction" is usually accomplished by adding capacitors to the system to counteract the inductance of large motors.


Can motor overheat be caused by poor power factor correction?

yes it doesent


How do you save energy with power factor correction?

Power-factor correction doesn't save energy. Power-factor correction is used to reduce that magnitude of the current drawn from the supply in order to minimise the cross-sectional area of the supply conductors and associated equipment -thus keeping down the cost of the supply circuits which are owned by the supply company. Power-factor correction doesn't apply to homes, but only to larger commercial or industrial premises. The electricity supply company will negotiate a value of power factor for the load, and apply a penalty charge to the customer if his load is not kept within that agreed value.


What is APFC panel?

An Automatic Power Factor Correction (Controller) panel is used to Save Energy by consistently maintaining higher power factor. Low Power Factor leads to poor power efficiency, thereby increasing the apparent power drawn from the distribution network. This results in overloading of Transformer, Bus bars, Switch gears, Cables and other distribution devices within the Industry or consumer area.With an APFC the energy producer can:Avoid Penalization for lower power factor.Enjoy incentives for higher power factor operation being extended to Industries by some Electricity Boards/ Companies.Optimize the connected load for improved plant load factor.Avoid manual disruption.Avoid high current consumption losses.Improvement in voltage regulation.Decrease Maximum Demand KVA, thus avoiding penalty and Demand Charges.


How do you design power factor correction module for 3 phase?

using vienna rectifier


How to connect 3 phase power factor correction capacitor?

how to connect power capacitor with 3 phase motor


Minimum acceptable value of power factor FOR LIGHTING and MOTOR CIRCUITS?

Usually for a power factor lower that 90% a service charge will be added to the monthly electrical bill. On power factor correction calculations try to get the power factor up to 95%.


What is the technique of improve the power factor?

Simple technique by adding PP capacitor with automatic power factor controller.