Most likely this is referring to the initial inrush that occurs when a transformer is energized. The core of a transformer is designed for a specific magnetic field strength; When a transformer is switched into a circuit, it usually will not be switched at exactly a voltage peak. When the voltage is at its' peak, the induced magnetic field will be at zero. If the switching occurs at a voltage zero, the magnetic field strength will attempt to climb to double the designed value; since the transformer core is not generally oversized to this degree, it will saturate. This causes large inflows of current to the transformer, and shows up as even harmonics (mainly second harmonics) in the current waveform. This settles out within a few seconds (generally) to a small energizing current, usually less than 1% of the transformer's rated current.
Oils are frequently used in medicine but transformer oil is strictly meant only for transformers.
The ratings state the limits on voltage and current for operating the transformer at full load. The rated voltage times the rated current gives the rated VA of the transformer. Transormers are not usually rated directly for power because this depends on the power factor of the load applied.
Center tap transformer is the such kind of transformer that is made to a point half way along a winding of a transformer.
why should we use pulse transformer rather than ordinary transformer
The function of the radiator ban in a transformer is to cool the transformer oil.
transformer
It is the current transformer core meant for metering.
U doht
In a transformer, or on general, if a material is easily magnetized it has low reluctance.
if used for charging-NO if used for supply voltage-yes
ideal transformer is that which has no power losses.if any transformer transfer power to secondary without power loss then that call a ideal transformer
storing of energy
All what you need to do is to check your charging system if it is working properly. Second thing you can check your charger-socket and your charger head i mean the transformer.
ideal transformer is that which has no power losses.if any transformer transfer power to secondary without power loss then that call a ideal transformer
the connection here meant for the connection of windings in three core or limbs of a transformer. it might be delta or star connected.
cheeths come from heaven
Sir I am Imran khan in nepal my problem is 6000KVA Step down Transformer is not charging. Transformer Pri- 33000V /105A Sec- 6900V / 502Atransformer all test (open & short circuit ) good . but problem is HT(IR)= value this time IR value 50M ohmBefore 3days HT(IR) = value is 7000M ohm suddenly start Transformer result is Transformer not charging & HT(IR) value is down 50M ohm.