A series motor is one in which the field windings are in series with the armature windings. So the torque is proportional to the square of the supply current.
'Shunt' is an archaic term for 'parallel'. So a shunt motor is one in which the field winding is in parallel with the armature windings. So the torque is proportional to the supply current.
A shunt DC motor connects the armature and field windings in parallel or shunt with a common D.C. power source. This type of motor has good speed regulation even as the load varies, but does not have the starting torque of a series DC motor
A shunt dc motor has quite different characteristics from a series motor. Wired in series, the same current passes through the armature and the field winding and it is most unlikely that a shunt motor would have a field winding that is suitable for this. Therefore a shunt motor cannot be wired as a series motor in general because its field winding is designed for only a small current.
A Stab-Shunt wound motor is a type of compound motor. Is has a field in series with the armature and also a field in parallel (shunt). You can tell the difference between the leads as the field in series with the armature has to be able to handle the amperage load of the armature itself. It will have leads identical in size to the armature. The key issue to watch for is wiring the shunt and the series field in opposition to each other. This will create a differentially wound motor (suicide motor). The fields will (in effect) offset each other as speed/current increases. The faster it rotates, the more the series field will cancel the shunt field. This is DC motors 101, less field = faster rotation. This can cause a runaway motor.
If it is a series motor it may still work. If it is a shunt motor it will not work , it will produce a humming noise and get heated. The shunt fields normally have high reactance so the field current will be drastically reduced, which may not be able to create the requisite torque.
A DC shunt motor is a motor using DC supply with the the inductor connected parallel to the armature.
applications of series motor
applications of series motor
A shunt DC motor connects the armature and field windings in parallel or shunt with a common D.C. power source. This type of motor has good speed regulation even as the load varies, but does not have the starting torque of a series DC motor
A shunt dc motor has quite different characteristics from a series motor. Wired in series, the same current passes through the armature and the field winding and it is most unlikely that a shunt motor would have a field winding that is suitable for this. Therefore a shunt motor cannot be wired as a series motor in general because its field winding is designed for only a small current.
aster
The torque on a series motor is determined by the square of the armature current and, so, is very large -much larger than that of a shunt motor. Consequently, on starting, with no back-emf being generated, the torque on a series motor can be dangerously high if the machine has no mechanical load.
A Stab-Shunt wound motor is a type of compound motor. Is has a field in series with the armature and also a field in parallel (shunt). You can tell the difference between the leads as the field in series with the armature has to be able to handle the amperage load of the armature itself. It will have leads identical in size to the armature. The key issue to watch for is wiring the shunt and the series field in opposition to each other. This will create a differentially wound motor (suicide motor). The fields will (in effect) offset each other as speed/current increases. The faster it rotates, the more the series field will cancel the shunt field. This is DC motors 101, less field = faster rotation. This can cause a runaway motor.
If it is a series motor it may still work. If it is a shunt motor it will not work , it will produce a humming noise and get heated. The shunt fields normally have high reactance so the field current will be drastically reduced, which may not be able to create the requisite torque.
the basic difference is ,in short shunt motor the series field winding wont carry any current under no load condition whereas in long shunt motors series winding will carry no load current.....
It could be anything, it depends on the design of the motor and whether it is a high-power or a low-power motor.
A DC shunt motor is a motor using DC supply with the the inductor connected parallel to the armature.
series controller, shunt controller,series-shunt controller,series-series controller