answersLogoWhite

0

The OPC was classified into three grades, namely 33 grade, 43 grade and53 grade depending upon the strength of the cement at 28 days when tested as per IS 4031-1988. If the 28 days strength is not less than 33N/mm2, it is called 33 grade cement, if thestrength is not less than 43N/mm2, it is called 43 grade cement, and if the strength is not lessthen 53 N/mm2, it is called 53 grade cement.

User Avatar

Wiki User

15y ago

What else can I help you with?

Continue Learning about Electrical Engineering

What is the difference between the E12 and E24 resistor series?

E12 ( 10%): 10 12 15 18 22 27 33 39 47 56 68 82 E24 ( 5%): 10 11 12 13 15 16 18 20 22 24 27 30 33 36 39 43 47 51 56 62 68 75 82 91 The basic difference is that the E24 have "extra" values between those of the E12. It's roughly midway between the E12 points. They're more expensive too. There's also an E6- it runs: 10 15 22 33 47 68 At the top end there's an E192- wildly expensive but extremely accurate. They're used in life-critical systems or super accurate industrial machines.


What dual capacitor goes with rheem ac model no. raka-024-jaz?

Part# 43-25133-03 (Dual Round). Part#43-25135 (Dual Oval). Both listed are OEM parts Rated 35/3 MFD - 370 VAC


What is BR meter?

It is a Butyro Refrective Index meter. Generally, it is used by Dairy Industry to measure the Brix of oil present in the milk. Milk oil basically are present in the BR range of 40-43. This BR set up is specially used to check adulteration in milk, if adulterated with external oil to increase the fat percentage in the milk.


How many address lines would be required for an 8K 16 module......12..13..14or15?

Here's a brute force approach to figuring this out:number of address lines ------------- possible addresses1 ------- 22 ------- 43 ------- 84 ------- 16....n ------- (2)^nSo, you need 12 addresses, or 2^12, to provide 4000 byte address locations for a 2 byte wide data bus (the 16 in the name).


What is the standard reading in megger testing to conclude that the equipment is passed and or failed?

Meggers send voltage thru the cables to determine the resistance between, meggers like the mj145 have multiple settings from 100 volts to 1000v, a Megger showing a good reading will show megaohms thru its full band, a bad one reading will be indicated by it either reading 0 ohms or less then 30 ohms (depends on the circuit and what's between the wires) a bad indicator can also be a steady reading at low voltage then at higher voltage it spikes to a low ohm, or a low voltage, like as if u just created a short. What that shows is at low voltage your insulator is fine, but at high voltage it blows thru it, normally that means your Insolator around your wire is damaged.

Related Questions

What is the difference in 43 and 40?

The difference between 43 and 40 is 3.


What is difference between 43 and 53 grade opc cement?

43 grade OPC Cement it denotes the compressive strength of concrete in 43 Mega pascals will attain in 28 days. it is normally used for pavements, Non RCC structures and which are not important for initial strength. where as 53 Grade OPC Cement it denotes the compressive strength of 53 Mega Pascals will attain in concrete with the 28days, and it is used for RCC strengths and which are important to gain initial strength.


What the grade of cement?

33 grade, 43 grade and the 53 grade cement (In India)


What are grade of cement?

33 grade, 43 grade and the 53 grade cement (In India)


What is 53 and 43 grade in cement industry?

charecteristic strength of Cement. 53N/MM2 and so on


What is the difference between 43 feet and 1545 feet?

It is 1542 feet.


What is the difference between 43 Celsius an 38 Celsius?

5 degrees


Why cement is 334353 grade and not 3040or 50 grade?

Cement is designated as 33, 43, or 53 grade based on its compressive strength measured in megapascals (MPa) at 28 days. The numbers represent the minimum strength achieved; for instance, 33 grade cement has a minimum strength of 33 MPa. The specific gradation is established to meet varying structural requirements, with 33 grade suitable for general construction, while 43 and 53 grades are used for higher strength applications. The absence of grades like 30, 40, or 50 is due to standardization practices in the industry, which focus on specific performance benchmarks.


Which grade cement is best for concrete roofing?

For concrete roofing, Grade 43 or Grade 53 cement is typically recommended due to their high strength and durability. Grade 53 cement, in particular, offers superior compressive strength, making it ideal for structures that require enhanced load-bearing capabilities. Additionally, using cement with low permeability can help improve the roofing's resistance to moisture and weathering. Overall, the choice between these grades may depend on specific structural requirements and local building codes.


What is the difference between 12 inch vs 516 inch?

A factor of 43?


What the difference between a 307 water pump and a 350 water pump?

43!!


What is the difference between a pitcher's plate and the home plate in softball?

43 feet