An unbalanced load prevents the generator delivering its maximum power. That is because each phase has an equal upper current limit that it can deliver, and in an unbalanced system, if one phase is delivering the rated current it follows that the others are not.
The electrical term for this condition is called an unbalanced load.
Droop CT is used to control load sharing of the reactive power b/w paralleled generators.
Any device that uses the generator to supply its operating voltage is electrically classed as a generator load.
If you have many Gas turbine Generators working on parallel, if any fault happened in one generator ( so this generator is no longer feeding the load ) load shedding panels will disconnect a group of predetermined Less important loads to help the working generators in the additional load (which may come after fault of the mentioned generator ).
three phase load is said to be balanced when the impedance and power factor of each load is equal.in this condition phasor sum of currents and phase voltages add up to zero.
Unbalanced Load was created on 2009-08-04.
To carry the unbalanced load current.
Paralleling generators involves connecting multiple generators to a common bus to share the electrical load. The procedure typically includes synchronizing the generators in terms of voltage, frequency, and phase before connecting them to the bus. Once synchronized, the generators can share the load based on their capabilities, with the load distribution influenced by their respective settings, such as governor control and droop settings. Proper load sharing is crucial to ensure that no single generator is overloaded, which can be managed through coordinated control systems that adjust output based on real-time load conditions.
No
If the [group of] forces on an object is unbalanced, the object accelerates.
A three-phase 'unbalanced' system refers to the load, as the supply voltages are unaffected by load. So the phase-angle and, therefore, the power factor of each phase will be different -i.e. there will be three different power factors.
If the load is connected in wye (star) and it has a neutral, then the vectorial-difference of the phase currents will flow in the neutral and there will be no problem. On the other hand, if there is no neutral, then an unbalanced load would cause unbalanced phase voltages.
The electrical term for this condition is called an unbalanced load.
You are, presumably, talking about an unbalanced three-phase load. The answer is no, because the wattmeter takes unbalanced loads into account.