answersLogoWhite

0

What else can I help you with?

Continue Learning about Electrical Engineering

If you put a 60W 120V bulb in a 120V lamp that has a transformer for 240V and plug it into a 240V outlet will it work or blow the circuitry?

Off hand no but your explanations are not clear as to who is doing what to whom,,


Can you get 120v single phase from 440 3 phase?

Yes, you can obtain 120V single-phase power from a 440V three-phase system using a transformer. By using a step-down transformer that reduces the voltage from 440V to 120V, you can safely access single-phase power. It's important to ensure that the transformer is correctly rated for the load and that all safety regulations are followed during installation. Always consult with a qualified electrician for any electrical work.


How do you get 120 volts from a 40 volt output?

To step up a 40-volt output to 120 volts, you would typically use a transformer designed for voltage increase, known as a step-up transformer. The transformer must have a turns ratio that corresponds to the desired voltage increase; in this case, the ratio must be 3:1 (120V/40V). Alternatively, you could use a DC-DC converter if the voltage is DC, which can also boost the voltage to the desired level. Always ensure that the components used can handle the power requirements safely.


What is a 24v transformer used for?

A 24v transformer converts 120v to a lower voltage for use in push buttons, like doorbells, thermostats, gas valves, or air conditioning systems. They are an essential tool for electricians.


Can you feed a 208v 200amp panel from 480v 20amp circuit?

Not directly, you would need to transform 480v circuit to 120v with a transformer first.

Related Questions

How do you calculate voltage ratio of Transformer?

Count the turns ratio of the windings. The voltage ratio is equal to the turns ratio. The current ratio is equal to the inverse of the turns ratio. For instance, a power transformer with a 10:1 turn ratio (primary to secondary) running on 120V will produce 12V. If it consumes 1 ampere from the input, it will provide 10 amperes to the output.


What kind of transformer for going from 120v to 220v?

This type of a transformer is known as a step up transformer.


If a 120v transformer has 200 turns the secondary winding has 20 turns what is the secondary winding voltage?

The ratio of AC voltages is the same as the ratio of winding-turns in the transformer. Vp / Vs = Np / Ns (10 volts AC) / Vs = 200 / 20 = 10 Vs = (10 volts AC) / 10 = 1 volt AC.


How do you get 480v circuit from 120v?

You can use a step-up transformer. Transformers are rated in primary voltage, secondary voltage, kVA, phases (single and three) and other parameters then equipped with indoor and outdoor enclosures. Be sure to consult a professional engineer or electrician when choosing and installing a step-up transformer. There are several NEC issues involved as well as choosing a transformer that is right for the type of load you have. One without the proper licensing AND knowledge of transformer circuits should never install 480V wiring or transformers.


How many amps can a 0.50 kva transformer give 277v input 120v output?

To determine the output current in amps for a 0.50 kVA transformer with a 277V input and 120V output, you can use the formula: Power (kVA) = Voltage (V) × Current (A) / 1000. For the output at 120V, the current would be calculated as follows: 0.50 kVA = 120V × Current (A) / 1000, which gives Current = (0.50 × 1000) / 120 ≈ 4.17 amps. Thus, the transformer can provide approximately 4.17 amps at the 120V output.


Example of electric potential?

120v


Why does my 120v 24v reduce to 28v. when you connect it to your boiler it blows out the transformer. is a problem with the transformer or the panel?

Please go to discuss question page.


Can 120V appliance work with 220V?

120V appliance will not work on 220V. Use an instrument transformer or voltage regulator to adjust the high voltage to the desired level.


Can you get 120V from 380V 3 phase?

Yes, you can obtain 120V from a 380V three-phase system using a transformer. By utilizing a step-down transformer designed to convert 380V to 120V, you can safely provide the desired voltage for single-phase loads. Additionally, you can also achieve 120V by using a phase-to-phase connection in a three-phase system, depending on the system configuration. However, it’s crucial to ensure that the transformer and wiring are properly rated for the application to ensure safety and efficiency.


Can you run your neon sign of 120v 50hz 60hz 0.6a 7.5kv 30mA in an Australian 240v power outlet?

No. The neon sign is fed by a step-up transformer. Primary side 120V, secondary side 7500V. If you applied 240 to the primary side you would get 15000 volts on the neon tube. A flash over and then nothing. If you can find a transformer from 120V to 240V or 240V to 120V then you are good to go. Connect 240V to 240V side and you will get 120V out the other, connect the 120V side to the neon sign and you should have light. Transformer should be at least 100va. This will give you an output of .83 amps at 120V


If you put a 60W 120V bulb in a 120V lamp that has a transformer for 240V and plug it into a 240V outlet will it work or blow the circuitry?

Off hand no but your explanations are not clear as to who is doing what to whom,,


How do you use 205V equipment on 120V?

You can use a transformer or voltage converter to step up the voltage from 120V to 205V for your equipment. Make sure to select a transformer that can handle the wattage and current requirements of your equipment to avoid damaging it.