Under voltage protection (release?) is used in industry. If there was a power failure and a piece of equipment was running when the failure occurred for safety reasons the machinery should not start up on its own when the power returns back on. With under voltage protection the operator restarts the machinery after checking that there is no danger to anyone and the machine is clear to start. To obtain this safety feature an electrical contactor is used in conjunction with remote stop - start buttons located at the machine the operator is working.

User Avatar

Wiki User

15y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: When use undervoltage release?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Electrical Engineering

What is prolonged undervoltage?

brownout


What is the purpose of under voltage protection of generators and motors?

An AC electric motor, powered directly from the AC grid, operating in traction of a given mechanical load, which presents characteristic of resistant torque constant, this means that it will need to develop an air-gap flux, also constant. In order that such electric motor to produce a flow of air gap constant, this means that both electrical current (i) that it demands, as the V / F (voltage / frequency) that it must operate, are both constant, too. If, by chance, the mechanical load is disconnected from the motor shaft, the flow is drastically reduced to a minimum, just enough to produce a minimal torque necessary to keep rotating, the rotor mass. In this case, both voltage and frequency of the AC power grid that feeds the motor, its values ​​are maintained, whereas the amount of current that the motor consumes falls proportionally to the torque that is produced by the motor, so that, by the electric motor windings, will flow only magnetizing current. Thus, the AC electric motors are manufactured, specified to operate powered directly from the power grid with a voltage and frequency, both predetermined. In this case, if there is any load variation (variation of the resistant torque), only the current it demands will vary, while the V / f ratio remains constant. However, if there is a need to vary the rotational speed of the electric motor shaft, this may be obtained by the purposeful variation of the frequency of its AC power. But necessarily concurrently, the voltage also must be varied in order to maintain the V / f constant. This is the working principle of the inverter frequency control scalar type. However, when operated fed directly from the AC mains, if for any failure of the electric grid, the voltage starts to fall in value (undervoltage), whereas the frequency value is maintained, it causes the air-gap flux motor falls , impairing thereby the torque produced. However, because of autoregulation inherent to the electric motor, it will seek, in contrast, automatically compensate for the loss of torque draining a higher current, trying thus recover the nominal flow and the ability to produce mechanical energy. The problem that occurs is as follows: the extent that decrease the supply voltage to the motor, the more increase the current flowing through the motor, causing it to overheat. Thus, the overall result of an undervoltage condition is an increase in current and motor heating and a reduction in overall motor performance, so that the motor must be protected against this. The undervoltage protection element can be thought of as backup protection for the thermal overload element. In some cases, if an undervoltage condition exists it may be desirable to trip the motor faster than thermal overload element. For this purpose can be used an undervoltage relay which removes the motor from service when a low-voltage condition develops, so that the motor will not draw excessive current and become itself overheated. The undervoltage trip should be set to 80-90% of nameplate unless otherwise stated on the motor data sheets. Motors that are connected to the same power grid may experience a temporary undervoltage, when one of motors starts and the other motor is ahead operating. To override this temporary voltage sags, a time delay setpoint should be set greater than the motor starting time. I believe that it should respond satisfactorily to your question, at least with respect to the occurrence of undervoltage, in the case of supply lines for AC motors.


What happens when a the electrical voltage is low?

Appliances at home have designated voltage e.g. 220 V or 110 V. When the voltage is dropped, the appliances try to run at their designated power in kW as usual. To keep the power same, current is increased (P = VI). This increase in current can burn the most delicate part of the appliances if the low voltage is experienced persistently.AnswerA drop in supply voltage results in a drop in the power of appliances. For fixed-resistance devices, a 10% drop in voltage results in approx, 18% drop in power.


Why do electric motors burnout?

I would guess by overloading or by running at too low a voltage which has the same effect.The amperage goes beyond the rated amperage if overloaded. If undervoltage but heavily loaded then the motor will attempt to draw more current to make up the loss in power and exceed the rated current.In either case the excess current saturates the magnetics and overheats the motor causing insulation breakdown on the windings (and that horrible smell) and you get what is popularly known as burnout. Once the insulation has broken down the motor loses most of its torque and would be considered failed.


Why you use capacitors in power supply?

You use a capacitor to store electrostatic energy. You use an inductor to store electromagnetic energy. You use a resistor to dissipate electrical energy.

Related questions

What is prolonged undervoltage?

brownout


Where you use undervoltage protection?

Undervoltage protection is provided for A circuit bars,motors, generators, transformers, rectifiers, etc.. Such protection is given by means of undervoltage relay. Undervoltage relay are necessary for voltage control and reactive power control of network buses and load buses. These type of relays have inverse time characteristics and their operating time reduces twith the reduction in operating voltage. Undervoltage protection is provided for AC circuit bars,motors, generators, transformers, rectifiers, etc.. Such protection is given by means of undervoltage relay. Undervoltage relay are necessary for voltage control and reactive power control of network buses and load buses. These type of relays have inverse time characteristics and their operating time reduces twith the reduction in operating voltage.


What is a 27 relay?

undervoltage relay


Cause of single phase capacitor start motor burning?

mainly due to undervoltage.


Difference between edo and mdo in air circuit breaker?

MDO = mechanical drwan out typr EDO = Electrical drwan out type( motor operated drwan out.


What is the difference between voltmeter and voltage sensor?

voltmeter-measure voltage through. voltage sensor-identify overvoltage/undervoltage.(related to power quality)


Why 3 phase diesel generators run undervoltage?

The excitation voltage is too low. Turn the field voltage "pot" to raise the field voltage while watching the output generator voltage.


What sport do they use tag and release?

What sport do they use tag and release. Fishing.


Which recreation do competitors use tag and release?

The recreation that competitors use tag and release is fishing.


How do use word release in a sentences?

please release the ball from your hand


What is the command line to use IPConfig to release the Current IP address?

ipconfig /release


Do cells use both respiration and fermentation to release energy?

Yes...Cells do use both Respiration and fermentation to release energy.