because our system form factor is 1.1
The different testing steps of HT and LT panel include commissioning, sanctioning, erection and the CPP set. All this is done in the servicing of the transformers and the HT/LT control panels.
LT is Low Tension - it means Low voltage. generally up to 440 Volts system is known as low voltage system
LT motors are those motor whose voltage rating is less than 415v.
Lt= 1/(1/L1+1/L2) Lt= 1/(1/.02+1/.05) Lt= 14.29 mH
long travelling and cross travelling meter
It's the voltage: HT high voltage LT low voltage Tension = voltage (French?)
Dielectric Strength of Vacuum is more than that of Air. In HT voltage is more than LT. So VCB is used in HT & ACB in LT. Rakesh Gaikwad
1 ampere in high-tension (HT) is equivalent to 1 ampere in low-tension (LT) systems. The difference between HT and LT lies in the voltage level they operate at, with HT systems operating at higher voltages than LT systems.
ht cable that means voltage level is high , it is obvious that power is going to remain same ,so if voltage rises ,current has to be lowered .since current level is less in ht cable therefore size (dia) is less compared to l.t cable , (p=v.i),lt cable current rating is more and voltage rating is less
Voltage transformer or potential Transformers are used in conjunction with Current transformers for metering and protection purpose in HT and LT power system.
LT motor abbrevation
The different testing steps of HT and LT panel include commissioning, sanctioning, erection and the CPP set. All this is done in the servicing of the transformers and the HT/LT control panels.
lt pannel is a iow tensan pannel. lt pannel work is 240v and 440v. ht pannel is a high tensan pannel . ht pannel work is 11kv,33 kv ,66kv, 120kv
The 1999, 2000, 2001 C70 engines that are HT are the 2.4 L Engines. The LT engine is the 2.3 L but it produces more horsepower than the HT.
Yes. For any problem or short circuit on LT side there are lot of chances for HT winding to get affected. Usaually the weakest point gets affected, it may be tap changer or the HV Windings. Electrix Vishnu
ht motor is to be fed with more than 415v like in kvolts. all the other operated below 415 volts are lt motors
A 'bushing' is a tubular insulator used to insulate a conductor that passes, for example, from the inside of a transformer or circuit breaker to the outside, enabling the internal components to be connected to external supply lines.High-voltage (or 'high tension') bushings have thicker walls and are longer than low-voltage bushings, as they have to withstand higher voltages.