I've seen it done, but be certain that the motor is connected to the correct VOLTAGE. The UK uses a 50Hz, 240V electrical system. The US uses a 60 Hz, 120/240V. The motor you are referring to was probably used in the UK, so will probably need 240V.

User Avatar

Wiki User

16y ago

What else can I help you with?

Related Questions

Is majora's mask Pal in 60Hz?

No 50Hz


What is the difference between 50Hz and 60Hz?

10HZ. Enjoi!


What can use to change a 110v 60cycle inverter 50cycle?

You can use a frequency converter to change the output frequency of the inverter from 60Hz to 50Hz. This will allow you to use devices that are rated for 50Hz frequency with your 110V 60Hz inverter. Just make sure to select a frequency converter that is compatible with the power output of your inverter.


How can you convert a 220v 50hz generator to a 220v 60hz?

you can't


How do you convert 50Hz to 60Hz Air Circuit Breaker?

You don't.


Can you play Far Cry 2 for Xbox 360 on a 50Hz TV?

No. It is a American game and they use 60Hz. So no.


How does 50hz and 60hz differ from one another?

ONE THING FOR SURE THERE IS NO CHANGE IN VOLTAGE IF SAME EQUIPMENT WE ARE TALKING ABOUT. THE ISSUE HERE IS THE CHANGING LOAD FREQUENCY 60HZ TO 50HZ OR VICE VERSA. FOR EXAMPLE THE MOTOR HORSEPOWER AND R.P.M. WILL BE APPROXIMATELY 90 AND 83 PERCENT OF THE NAMEPLATE SPECIFICATIONS, ALSO THE FULL LOAD RUNNING TORQUE WILL INCREASE APPROXIMATELY 8 PERCENT IF USED FROM 60HZ TO 50HZ.


Is 380 votage considered 50hz or 60hz?

Voltage has nothing to with frequency


How can you interconnect two generating station operationg at 60Hz and 50Hz?

Through the use of a high-voltage direct-current link.


How can you determine if an electric motor is 50HZ or 60HZ if there is no name plate?

One way would be to hook it up to a supply (by itself, with no load) and measure the speed with a contact tachometer. If your supply is 60Hz, and the motor speed corresponded to one of the standard motor speeds, it would be a pretty safe bet you had a 60Hz motor. If the speed was about 20% faster than a standard speed, the motor is probably a 50Hz motor. Or 20% slower if you were running a 60Hz motor on 50Hz For instance, a 1750 RPM 50Hz motor would spin at about 2100 RPM if you ran it on 60Hz.


Can you use a 220v-60hz microwave in Australia?

Yes, using a 220v-60hz microwave in Australia is fine. The voltage of alternating current supplied to homes in Australia is 220v. The frequency of the voltage is 50hz.


Will a 230V 50Hz drain pump of a washing machine work on a 220V 60Hz?

No! Normally not, the recistance in the windings is to hig on 60Hz and the pump motor has not power enough to work propelly. This happened to myself when I connected my Whirpool AWE 7519 to 230V 60Hz. Europian model for 50Hz.