rotating anode
1)During a operation large shaped disc tungsten anode rotate at speed 3000 t0 9000rpm(resolution per minute).
2)A motive force to rotate the anode is given by induction motor.therefore windings of which is housed outside the tube.
3)a design element help to limit power density delivered on the physical focal spot while making a small effective focal spot.
4)with rotating anode,heat is produced during exposure is spread over the large area of anode.thereby increases the heating loading capacity of the tube and allowing high power level are used as a result which produces the x radiation.
5) by increasing the anode voltage x rays which produces the shortest wavelength this is used to therpeutic.
by decresing the anode current which produces the longest wavelength this is used for diagnostic process.
A rotating anode promotes cooling between exposures by distributing the intense beam from the cathode over the surface of the anode. A rotating anode tube lasts a lot longer than a stationary x-ray tube.
There is no such thing as anode rays. The cathode rays (aka electron beam) just travels from cathode to anode.
Cathode ray.
The negatively charged electrode of a cathode ray tube (CRT) is the cathode. The tube is a cathode ray tube, and electrons stream off the cathode, are accelerated across the evacuated space and "directed" either electromagnetically or electrostatically, and then strike the phosphor coating on the positively charged anode at a "location" determined by the "directing" elements.
Cathode Ray
A rotating anode promotes cooling between exposures by distributing the intense beam from the cathode over the surface of the anode. A rotating anode tube lasts a lot longer than a stationary x-ray tube.
An x-ray tube where the anode is held still, rather than rotated as would happen in the rotating anode tube.
The x-ray tube target is rotated to reduce wear and tear on the anode and to keep the anode from overheating.
The cathode of an electron gun.
A cathode ray tube (CRT) emits light when electrons strike the front of the glass tube that is covered in a phosphor coating. The front of the tube is the anode of the tube. The electrons are fired from the rear of the tube by an electrode called the cathode. The electrons are formed into a beam or ray, hence the name of cathode ray tube. Although the electrons travel from the rear of the tube to the front, or from the cathode to the anode, conventional current actually flows the opposite direction. So, the current, as measured in amps will flow from the anode to the cathode.
Yes they are the same. A cathode ray tube (CRT) uses an electron gun to "shoot" electrons from the cathode to specific positions on the anode of the CRT.
The normal anode angle in a diagnostic x-ray tube is usually around 12-17 degrees. This angle helps to distribute heat and increase the efficiency of x-ray production by allowing for better dissipation of heat generated during the x-ray process.
There is no such thing as anode rays. The cathode rays (aka electron beam) just travels from cathode to anode.
when the cathode filament emits the electron and because of the high vaccum inside the tube with a high voltage who is applied on anode (the destination) the electron will accelerate to the anode and the anode will emits the x-ray photon directly after strike of the mentioned electron. the power of x-ray or peneration is determined of the anode high voltage.
In X-ray tubes, electrons are emitted from a cathode source to a anode target through a process called thermionic emission. Electrons are then accelerated towards the anode target via a potential energy difference between the cathode and anode. The interaction between the accelerated electrons and atoms in the anode target causes the emission of X-ray. Efficiency of the X-ray tube is impaired by the kinetic energy of the accelerated electrons being loss as heat and only 1% of the remaining energy is used to emit X-ray.
Anode ray is positive and cathode ray is negative
This point, the place where the electron beam strikes the anode, is generally called the target.