Most newer buildings have some kind of an air conditioning system. But, it would certainly depend on where one is, and the type of building.

Many northern and north western cities tend to be cool enough that many homes don't have or use AC systems. And, I'd assume the buildings would be similar. One might still want some kind of air circulation system.

Big warehouse like buildings (Home Depot & etc) might not be efficiently cooled by AC systems, and they might be left out.

Once I worked in a wood factory. It had a huge blower system. I don't remember the exact numbers, but I think they said it essentially replaced 100% of the air in the building every 10 minutes or so. We had local space/workstation heaters for use in the winter, but AC units would be pointless in the summer.

Although, people tend to be a lot more demanding in office buildings than in factories.

User Avatar

Wiki User

∙ 16y ago

What else can I help you with?

Continue Learning about Engineering

How many types of industrial chiller in the world?

there are three type of different chiller 1- Air 2- Water 3- Evaporative Condencer Chiller By # Zish Siraj From Karachi 00923212170310


Does a condo unit require a fire safe door?

NO... but all building require two ways to exit the building if there is a fire ...(if its more then 2 stories high)


What is the work of Variable Frequency Drives panel in Chiller Plant?

Vfd is used for maintaing the pressure of whole chiller line.


Where is the worlds biggest chiller?

NIH in Maryland


Why are variable frequency drives used for secondary chilled water pumps?

In a chilled water system, the chillers are happiest with a constant-volume flow. In a primary-secondary loop system, the chiller has a primary pump that is constant-speed. If that were the only pump, and it circulated chilled water through the chiller and the load (air handler, etc.), imagine what would happen as the temperature setpoint was reached. The control valve starts to close, reducing the flow. This deadheads the pump, which is bad in itself, but it also reduces flow through the chiller. The chiller could be damaged, or it would trip on a low flow safety, or at the very least it operates poorly, or inefficiently. You could change the control valve to a three-way diverting valve. Now instead of closing, upon reaching setpoint the valve diverts some of the flow, bypassing the load, and recirculates it back to the chiller. This maintains full flow through the system, but it wastes energy because you are always pumping full-load flow even in the dead of winter when you may only need a fraction of the system's capacity. What if there was a way to maintain a constant flow through the chiller, yet only supply just the needed flow to the building? Well, let's change the control valve(s) back to standard 2-way, and add a secondary pump with VFD. We will also need a pressure sensor on the secondary loop. We add a bypass pipe between the two pumps. Can you visualize the piping? Water leaves the primary pump, goes through the chiller, heads out on the CHW supply line. Then it can either circulate through the bypass line and back to the pump (that's the primary loop), or keep on going out to the building, then back from the building, through the secondary pump, past the bypass line, and to the suction on the primary pump. The beauty of the primary-secondary system is we can reduce secondary flow to the building as the cooling load reduces. As the control valve(s) close, the pressure in the secondary loop rises. The pressure sensor detects this and slows the pump down to maintain a constant pressure. As less and less water flows from the chiller out to the building, more and more of the primary flow goes through the bypass pipe, maintaining constant GPM through the chiller. You save money several ways. It takes horsepower ($) to overcome pumping friction losses as you move all that water through the hundreds or even thousands of feet of building piping. Reducing the secondary flow saves energy. Two-way valves are cheaper, less complex, and easier (cheaper) to install. The chiller always operates at design flow, where it is more efficient. So, the VF drive is needed to allow the control system to vary the secondary pump GPM to maintain constant secondary loop pressure as the load requirements change.

Related Questions

Where is The Building supervisor is connected directly to the chiller and?

The building supervisor is typically connected directly to the chiller within the building's HVAC system. This connection allows for real-time monitoring and control of the chiller's operation, ensuring optimal performance and energy efficiency. By receiving data from the chiller, the building supervisor can promptly address any issues and maintain a comfortable environment for occupants.


What is the relation between ahu and chiller?

Ahu (air handling unit) and chiller are both components of a building's HVAC system. The AHU is responsible for circulating and conditioning air, while the chiller is responsible for cooling the water that circulates through the building to remove heat. The AHU uses the chilled water from the chiller to help control the temperature and humidity levels in the building.


When a chiller is used the secondary refrigerant that circulates in the building is?

Water


What is the difference between chiller and freezer in industrial equipment division?

chiller and freezer is same, tem is different, require tem for chiller is 0-5*C, & freezer is tem should be -18*c & above


What is the different between chiller and ductable system?

The air conditioning machine that cools the water is called a chiller, and it will be located in a dedicated machinery area somewhere in the building, on the roof, or outside.


What is negative flow and positive flow in chiller plant?

Negative flow in a chiller plant refers to the flow of chilled water returning to the chiller plant. Positive flow refers to the flow of chilled water leaving the chiller plant to cool the building or process. Proper flow direction is crucial for efficient operation of the chillers and the overall system.


How do you maintain the effectiveness and efficiency of Chiller Plants for long term?

Chiller Plants require regular maintenance for there smooth running for long time.Following are some tips that will help you to maintain there efficiency:Inefficient operating processes is one of the key reasons of chiller inefficiency. An industrial chiller manufacturer states a limit of the flow rate in order to ensure that the chiller works efficiently.Accurate entry of the details in the log can help comparing the performance and detect the problems in the chiller in advance.The performance of the chiller is directly related to the ability of the transfer in heat. The heat transfer efficiency depends on how clean and well maintained it is.Hope it will help you.


How do you use a glycol chiller in my brewery?

Glycol chiller used when beer brewing. This tasked with cooling the propylene glycol. its a food grade anti freeze which require to cool food products.But there are some restriction to use propylene and must to follow the USP grade.Its need chiller system which evolve with compressor, evaporator,condenser and pump. You can read a article from kinnek.com where lot of information available about glycol chiller.


What is an Australian portable drinks chiller?

Maybe you are referring to the Esky- every Australian owns at least one.


How many ice rinks are part of the Chiller Ice Rink group?

The Chiller Ice Rink Group operates five rinks in the Greater Columbus, Ohio area. The rinks in the group are: Chiller Dublin, Chiller Easton, Chiller Ice Works, Chiller North, and Ice Haus.


What are the release dates for Chiller Cinema - 1999 Chilly Billy Chiller - 4.13?

Chiller Cinema - 1999 Chilly Billy Chiller - 4.13 was released on: USA: 2002


How many amps does a wine chiller use?

Depends on the size of the wine chiller. There should be a label on the chiller with this information.