The air conditioning machine that cools the water is called a chiller, and it will be located in a dedicated machinery area somewhere in the building, on the roof, or outside.

User Avatar

Wiki User

13y ago

What else can I help you with?

Continue Learning about Engineering
Related Questions

What is the difference between vrv system and chiller?

Chiller uses chilled water while vrv uses refrigerant directly


What is delta T on the chiller?

Delta T on a chiller refers to the temperature difference between the fluid entering and exiting the chiller. It is a critical parameter that indicates the efficiency of the cooling process; a larger delta T typically signifies better performance as it means the chiller is effectively removing heat from the fluid. Monitoring delta T helps in assessing system performance and identifying potential issues. Ideally, delta T values depend on the specific application and design of the chiller system.


What causes high pressure in chiller system?

dirty coil


What is the relation between ahu and chiller?

Ahu (air handling unit) and chiller are both components of a building's HVAC system. The AHU is responsible for circulating and conditioning air, while the chiller is responsible for cooling the water that circulates through the building to remove heat. The AHU uses the chilled water from the chiller to help control the temperature and humidity levels in the building.


Why must water be circulated through a chiller during a refrigerant evacuation?

When evacuating refrigerant from a chiller system, circulating water through the chiller helps dissipate the heat generated during the evacuation process. This prevents the chiller components from overheating and ensures efficient and safe evacuation of the refrigerant. It also helps maintain the chiller's operational efficiency.


Excessive running of a purge system on a low pressure chiller condition?

Excessive running of a purge system on a low-pressure chiller can indicate issues such as refrigerant leaks or improper system charging. This can lead to inefficiencies, increased energy consumption, and potential damage to the chiller components. Prolonged operation of the purge system may also result in the loss of refrigerant, impacting system performance and necessitating costly repairs. It is essential to diagnose the underlying cause to ensure optimal chiller operation and prevent further complications.


What does a flow switch do in a chiller?

A flow switch in a chiller detects if there is enough flow of cooling water through the system. If the flow drops below a certain threshold, it can trigger an alarm or shut down the chiller to prevent damage from overheating. The flow switch helps ensure that the chiller operates efficiently and safely.


What is a RRU in a chiller system?

Something technical i think you should ask someone


How water chiller works?

Water cooled chiller work on principal that water is circulated in condenser for removal of heat from the system and refrigerant gas is thus condensed in condensor.


What preventative maintenance do chiller service companies offer?

Preventive maintenance for chiller service companies offer Cleaning, Monitoring pressure and the temperature and then general system testing.


Wiring system for use in supplying a chiller unit in a farm diary?

The wiring system in all probability will be a three phase system.


If a comfort control system also supplies heat the heaters are normally located where?

chiller