answersLogoWhite

0

rotating anode

1)During a operation large shaped disc tungsten anode rotate at speed 3000 t0 9000rpm(resolution per minute).

2)A motive force to rotate the anode is given by induction motor.therefore windings of which is housed outside the tube.

3)a design element help to limit power density delivered on the physical focal spot while making a small effective focal spot.

4)with rotating anode,heat is produced during exposure is spread over the large area of anode.thereby increases the heating loading capacity of the tube and allowing high power level are used as a result which produces the x radiation.

5) by increasing the anode voltage x rays which produces the shortest wavelength this is used to therpeutic.

by decresing the anode current which produces the longest wavelength this is used for diagnostic process.

User Avatar

Wiki User

13y ago

What else can I help you with?

Related Questions

Difference between rotating anode x ray tube and stationary x ray tube?

A rotating anode promotes cooling between exposures by distributing the intense beam from the cathode over the surface of the anode. A rotating anode tube lasts a lot longer than a stationary x-ray tube.


What are stationary anode x ray tubes?

An x-ray tube where the anode is held still, rather than rotated as would happen in the rotating anode tube.


The purpose of rotating the X-ray tube target is to?

The x-ray tube target is rotated to reduce wear and tear on the anode and to keep the anode from overheating.


What is the source of electrons in the x-ray tube?

The cathode of an electron gun.


What is the direction of current in picture tube of TV?

A cathode ray tube (CRT) emits light when electrons strike the front of the glass tube that is covered in a phosphor coating. The front of the tube is the anode of the tube. The electrons are fired from the rear of the tube by an electrode called the cathode. The electrons are formed into a beam or ray, hence the name of cathode ray tube. Although the electrons travel from the rear of the tube to the front, or from the cathode to the anode, conventional current actually flows the opposite direction. So, the current, as measured in amps will flow from the anode to the cathode.


Is cathode ray tube and electron tube same?

Yes they are the same. A cathode ray tube (CRT) uses an electron gun to "shoot" electrons from the cathode to specific positions on the anode of the CRT.


What is the normal anode angle diagnostic x-ray tube?

The normal anode angle in a diagnostic x-ray tube is usually around 12-17 degrees. This angle helps to distribute heat and increase the efficiency of x-ray production by allowing for better dissipation of heat generated during the x-ray process.


In cathode ray tube cathode and anode rays travel opposite to each other but they are not neutralized. why?

There is no such thing as anode rays. The cathode rays (aka electron beam) just travels from cathode to anode.


How are cathod rays produced?

when the cathode filament emits the electron and because of the high vaccum inside the tube with a high voltage who is applied on anode (the destination) the electron will accelerate to the anode and the anode will emits the x-ray photon directly after strike of the mentioned electron. the power of x-ray or peneration is determined of the anode high voltage.


Why is the x-ray tube considered an inefficient device?

In X-ray tubes, electrons are emitted from a cathode source to a anode target through a process called thermionic emission. Electrons are then accelerated towards the anode target via a potential energy difference between the cathode and anode. The interaction between the accelerated electrons and atoms in the anode target causes the emission of X-ray. Efficiency of the X-ray tube is impaired by the kinetic energy of the accelerated electrons being loss as heat and only 1% of the remaining energy is used to emit X-ray.


Differentiate between anode ray and cathode ray?

Anode ray is positive and cathode ray is negative


In the vacuum tube of the X-ray machine what is the point where the electron beam interacts with the anode called?

This point, the place where the electron beam strikes the anode, is generally called the target.