Related Questions

How do you calculate the steam flow rate?

The steam flow rate can be calculated by dividing the mass flow rate of the steam by the specific volume of the steam at the given conditions. This can be determined using steam tables or steam property calculators. The formula to calculate steam flow rate is: Flow rate (lb/h) = Mass flow rate (lb/h) / Specific volume (ft^3/lb)


How to calculate square root in DP flow transmitters?

Don't stop believing'… hold onto that feelin'


Why dp created for flow measurement?

The primary element creates a pressure drop across the flow meter by introducing a restriction in the pipe, and this engineered restriction enables Bernoulli's equation to be used for a flow rate calculation.


How to calculate DP ratio?

Stock+debtors-creditors/sale


What is the formula for finding the rate of change of a quantity with respect to time, known as the dp dt formula?

The formula for finding the rate of change of a quantity with respect to time, known as the dp/dt formula, is: dp/dt (change in quantity) / (change in time)


What is the dp/dt formula and how is it used to calculate the rate of change of pressure with respect to time in a given system?

The dp/dt formula represents the rate of change of pressure with respect to time in a system. It is calculated by taking the derivative of the pressure function with respect to time. This formula is commonly used in physics and engineering to analyze how pressure changes over time in various systems.


What is valve cv?

Cv is a capacity rating for a valve. A valve with a Cv = 1 will flow 1 gpm of water with a differential pressure of 1 psi. If the Cv was 100, it would flow 100 gpm of water with a 1 psi differential pressure. For non-flashing/cavitating service, Q = Cv * (dP/SG)^0.5. Q is the flow rate in gpm (US gal), dP is the differential pressure in psi and SG is the liquid's specific gravity.


How dp you calculate volume?

The answer depends on the shape and also on what information is provided, in what form.


What does cv rating mean on a water valve?

The CV value is the flow rate required to generate 1 psid of pressure loss through the valve. Since pressure drop follows a basic square law the relationship between Cv, flow and pressure loss is as follows: DP = k x Flow^2 eq 1 Where k is a constant that represents the flow shape in the wide open condition. Since Cv is the flow rate at 1 psi of pressure loss then it follows that DP = k x Cv^2 = 1 eq 2 solving for k from eq 2 yields k = 1/Cv^2 eq 3 substituting eq 3 into eq 1 yields DP = (Flow/Cv)^2 Now you have an equation that will tell you the pressure and flow relationship for that particular valve with a particular fully open Cv value. In short, the higher the Cv value the more flow the valve will allow for the same pressure loss or the less pressure loss for the same flow. Good luck


What is the formula for finding the permeability of materials?

The Darcy fluid flow equation: u = q / Ac = ( - k / µ . dp / dI ) Where: u = fluid velocity, cm/s. q = flow rate cm3/s k = permeability of the porous rock, Darcy (0.986923 µm2) Ac = cross-sectional area of the rock, cm2 µ = viscosity of the fluid, centipoises (cP) I = length of the rock sample, cm dp / dI = pressure gradient in the direction of the flow, atm/cm.


Difference between pressure regulating valve and differential pressure valve?

Pressure Differential Valve- maintains a constant Differential pressure across it. Say if P1 was inlet pressure and P2 was outlet pressure PDV will try to keep constant DP. Say if P2 increases due to some reason and P1 is constant the DP will decrease and will decrease flow through the PDV. At this point to maintain the constant DP PDV will open and allow more flow through to keep the flow constant and thus DP constant.


What is difference between profibus dp and profibus pa?

First I think I should point out that Profibus-PA instruments do not use RS-485 (such as is used by Profibus-DP), but a MBP (Manchester Coded, Bus Powered) physical layer, as described in the IEC 61158-2 standard. This is why you need a bus coupler to 'translate' the signals from Profibus-DP to Profibus-PA, and to power the PA bus. The maximum transmission rate of Profibus DP network 12Mbps The maximum transmission rate of Profibus PA network 45.45Kbps You need to power the DP instruments, while PA instruments get its power and exchange data via the same PA cable . You need DP/PA link or DP/PA coupler to link DP network with PA . when you use a coupler connected directly to the DP network , then your DP network transmission rate would be decreased to 45.45. From Pradip