If you are referring to a P trap under a sink, you loosen a large nut at each end and remover the entire P trap. If there is no nut at the downstream end, then you cut the pipe. If you don't know how, call a plumber,it's a very simple job.

User Avatar

Wiki User

11y ago

What else can I help you with?

Continue Learning about Engineering

Can you have a p trap waste pipe on a toilet that is on the ground floor?

You CAN'T have a p-trap under the toilet! The p-trap is built into the toilet!


What is p trap?

In plumbing, a trap is a U-, S-, or J-shaped pipe located below or within a plumbing fixture.


Can CLR be used on a plugged drain?

It won't do you any good. If the blockage is undersink, remove the P-trap and clean it out. If further down pipe,then snake it from there while P-trap is off.


How do you get sand out of a p trap?

Remove the trap and clean it out. If it is all PVC and glue jointed, cut the pipe above and below the trap, clean it out and glue it back together with couplings.


How do you know if you have a p trap?

If you can look under the sink, lavatory, or perhaps in the basement under the washing machine . . . a P trap is the drain pipe coming out of the bottom of the sink, or whatever. If that drain pipe goes down, then curves and goes up again, then goes sideways into the wall, then it is a P trap, so named because it look like the letter P if you hold your head just right and squint a lot. The other common trap is an S trap . . . it's the same as the above, except instead of the drain pipe entering the wall, it curves down, again, and goes down through the floor. Its shape is similar to the letter S, if you hold your head just right yada yada. If the drain pipe goes straight down into the floor or has an elbow, making it go through the wall, then there may be no trap at all. (Maybe: . . . the P trap for my bathtub may be found by tearing into the ceiling on the next floor down . . .)

Related Questions

Can you have a p trap waste pipe on a toilet that is on the ground floor?

You CAN'T have a p-trap under the toilet! The p-trap is built into the toilet!


How is a p-trap connected to a drain pipe?

A p-trap is connected to a drain pipe by being installed underneath the sink or fixture. The curved shape of the p-trap holds water to prevent sewer gases from coming back up the drain pipe.


What are the bell trap s trap drum trap p trap for?

P-trap is to prevent gasses from passing thought the pipe. For example, in a residential setting, a p-trap is installed on all residential drains in order that sewer gases do not use the pipe as a conduit and enter the home.


How is a p-trap connected to a drain pipe in a plumbing system?

A p-trap is connected to a drain pipe in a plumbing system by being installed underneath the sink or fixture. The p-trap is shaped like the letter "P" and traps water to prevent sewer gases from entering the building. The curved shape of the p-trap holds water in the bend, creating a barrier that blocks odors from coming back up the drain pipe.


How do I properly install a p trap assembly in my plumbing system?

To properly install a p-trap assembly in your plumbing system, follow these steps: Cut the pipe to the correct length. Attach the p-trap to the drain pipe. Connect the trap arm to the drain pipe. Secure all connections with slip nuts and washers. Test for leaks by running water through the system.


Is it okay to have two p traps in a 2 inch shower drain line i am unsure if p trap is under the slab and have a 2 inch PVC pipe stubbed out of cement.?

If you have an existing shower with a 2" line 'stubbed out of cement', it more than likely has a P-trap underground. An easy way to tell is to get a flashlight and look down the pipe; if you can see water standing in the pipe, there is a p-trap. No water, no trap. Double trapping a fixture is not recommended.


What is p trap?

In plumbing, a trap is a U-, S-, or J-shaped pipe located below or within a plumbing fixture.


What are the differences between an S-trap and a P-trap in plumbing systems?

An S-trap and a P-trap are both types of traps used in plumbing systems to prevent sewer gases from entering a building. The main difference between them is their shape and design. An S-trap has a curved pipe that forms an "S" shape, while a P-trap has a curved pipe that forms a "P" shape. P-traps are more commonly used today because they are less likely to siphon dry and allow sewer gases to enter the building.


Washing machine stand pipe is above and p trap is below bathroom floor p trap hooks to house drain then hooks to house vent stack that is 6 inches or more above p trap is this safe and efficient?

No


How do you install pipe without p-trap?

You need aP-trap under every sink. Get a plumber if you don't know what you are doing.


What happens if you don't have a p-trap in you kitchen sink?

WIthout a P-trap or a goose-neck, it will allow odors and fumes and maybe varmints to come back up the pipe.


What is the purpose of a p trap pipe in a plumbing system?

The purpose of a p-trap pipe in a plumbing system is to prevent sewer gases from entering the building and to maintain a water seal that allows waste to flow out while blocking odors from coming back in.