I think it's a test for a shorted armature.
It does have armature resistance.
Armature reaction is the effect of armature flux on the flux generated by the fied windings.Cross magnetisation and Demagnetising are its consequences.
this is wer the armature conductors ar being mounted,therefor it helps the flexibility of armature conductors.
Difference between field controlled and armature controlled is that field control is open loop and armature current is closed loop.
I think it's a test for a shorted armature.
An ohm meter.
Connect the SCR in series with the armature or field and control the firing angle of the SCR which in turns determine the current flowing to the armature or field.
If you connect the test leads to the brushes of a DC electric motor, you would typically measure the resistance across the armature circuit. This reading can help you determine the condition of the armature winding, the brushes, and the connections.
armature reactant means loss in armature associated with inductive properties of the coil, while armature reaction include losses due to magnetizing component of current flowing through armature.
It does have armature resistance.
No.it is not applicable for dc series motor at no load..at no load armature current is too small in dc series motor and we know that speed is inversly proportional to the armature current(speed=v/kI-Ir/k).Hence speed is dangerously high which is not efficient for Swimburne's test...
The main difference between a 12-volt armature and a 24-volt armature is the voltage rating at which they operate. A 12-volt armature is designed to run on a 12-volt electrical system, while a 24-volt armature is designed for a 24-volt electrical system. This difference determines the power and speed capabilities of the armature when used in electrical devices.
Armature reaction is the interaction between the magnetic flux produced by armature current and that of the main magnetic field in an electric motor or generator.
Armature reaction is the effect of armature flux on the flux generated by the fied windings.Cross magnetisation and Demagnetising are its consequences.
this is wer the armature conductors ar being mounted,therefor it helps the flexibility of armature conductors.
synchronous impedance can be calculated by performing oc test and sc test. by oc test,since the armature current is zero Vt=Ef . in short circuit test ,entire emf is consumed in circulating the short circuit current Isc,through the synchronous impedance. Zs=Ef/Isc.= (open ckt. terminal voltage for a certain field current)/(short ckt. current at the same field current)