answersLogoWhite

0

A Single phase induction motor includes a main winding, an auxiliary winding, a run capacitor, & a subsidiary star device. The auxiliary winding is configured such that the number of turns of the aauxiliary winding through which a current flows, varies according to the operating mode of motor. When the motor starts, the number of turns of the auxiliary winding through which a current flows is reduced there by increasing the start efficiency of the motor. when the motor runs in normal mode, the number of turns of auxiliary winding through which a current flows is increasing there by increasing the operations efficiency of motor

User Avatar

Wiki User

15y ago

What else can I help you with?

Related Questions

Why 2 phase induction motors are not used in industries?

A two-phase* system is archaic, and has been completely superceded by three-phase systems, so there is no demand for two-phase induction motors. (*A two-phase generator has two phase windings, displaced from each other by 90 degrees.)


Self starting single phase induction motors are also called?

Split Phase Induction Motor.


Disadvantages of 3 phase induction motor?

One of the disadvantages of the 3 phase induction motor is that it requires a three wire supply. The other disadvantage is that the 3 phase induction motors have poor starting torque and high have in the rush currents.


Is 3 phase induction motor is self starting?

Yes, that is one of the major advantages of a three-phase induction motor.


How single-phase induction motor classified?

The single phase induction motors are made self starting by providing an additional flux by some additional means. Now depending upon these additional means the single phase induction motors are classified as: 1.Split phase induction motor. 2.Capacitor start inductor motor. 3.Capacitor start capacitor run induction motor. 4. Shaded pole induction motor.


Theory for brake test on three phase induction motor?

why three phase induction motor is delta connected


What are the advantages of open end winding induction motor over conventional induction motor?

Open ended induction motor - i assume you are talking about split phase induction motor. With these motors old style speed controlling method using external resistors can be used. However this is now obsolete.


What has the author Eugene A Klingshirn written?

Eugene A. Klingshirn has written: 'Analytical and experimental study of high phase order induction motors' -- subject(s): Automobiles, Electric, Electric Automobiles, Electric motor vehicles, Electric motors, Induction, Electric propulsion, Equivalent circuits, Induction Electric motors, Induction motors, Stators


Do all single phase motors have a start and run winding?

No, commutator motors as used in vaccum cleaners for example do not use a starting winding. Single-phase induction motors need a starting winding without which they will start in either direction if given an initial twist.


What has the author Lester Eugene Stutz written?

Lester Eugene Stutz has written: 'The design of an induction motor, single phase double current generator set' -- subject(s): Electric motors, Induction, Induction Electric motors


How many microfarad of starting capacitor is best for 15hp 3phase motor?

Starting capacitors are only required for single-phase induction motors. They are not necessary for three-phase motors.


Revolving field theory of single phase induction motors?

The revolving field theory of single-phase induction motors suggests that a rotating magnetic field created by current flowing through two windings (main and auxiliary or starting winding) produces a starting torque in the rotor. This theory explains how single-phase motors can operate without the need for a separate rotating magnetic field, as in three-phase motors, by using a split-phase or capacitor start design to generate a rotating magnetic field.