In long shunt the shunt field winding is in parallel to both generator and series field. In short shunt the shunt field is in parallel to generator only.
the basic difference is ,in short shunt motor the series field winding wont carry any current under no load condition whereas in long shunt motors series winding will carry no load current.....
A series reactor is connected in series with a power system component, such as a transmission line or generator, to limit short-circuit currents and manage voltage drop during load fluctuations. In contrast, a shunt reactor is connected in parallel to the system, primarily used to absorb reactive power, improve voltage stability, and mitigate voltage rise in long transmission lines under light load conditions. Essentially, series reactors focus on current limiting, while shunt reactors focus on reactive power management.
Connect the circuit as per the circuit diagram shown in fig1. Keep the field regulator of the motor in the minimum resistance position and regulator of the generator in the maximum resistance position.2. Switch on the supply and start the motor with the help of its starter.3. Adjust the field regulator of the motor such that it runs its rated speed given on thename plate.4. Adjust the armature regulator of the generator to build up its rated voltage given on itsname plates on no load.5. Note down the no loads of ammeter and volt meter in tabular form.6. Increase the load gradually in steps and tabulate the readings7. Plot the external characteristics is load current Vs terminal voltage.8 Connect the generator for differentially compounding, repeat the process and plot theexternal characteristics.
Shunt compensation refers to the use of shunt capacitors or inductors in electrical power systems to improve voltage stability and reactive power management. By connecting these devices parallel to the transmission line, shunt compensation can help regulate voltage levels, enhance system reliability, and reduce losses. This technique is often employed in long transmission lines to counteract the effects of reactive power flow and maintain optimal operating conditions. Overall, shunt compensation plays a crucial role in improving the performance and efficiency of electrical networks.
Some of them are long and some are short.
when the current is passing through the winding then it is called "Excitation". Types of excitation (1)seperately excited generator. (2)self excited generator. self generator is classified into 3 types. 1.shunt generator. 2.series generator. 3.compound generator. compoud generator is again classified into 2 types. 1.short shunt generator. 2.long shunt generator.
when the current is passing through the winding then it is called "Excitation". Types of excitation (1)seperately excited generator. (2)self excited generator. self generator is classified into 3 types. 1.shunt generator. 2.series generator. 3.compound generator. compoud generator is again classified into 2 types. 1.short shunt generator. 2.long shunt generator.
the basic difference is ,in short shunt motor the series field winding wont carry any current under no load condition whereas in long shunt motors series winding will carry no load current.....
Two things could have occurred. (1) wrong direction of rotation causing loss of residual magnetism or (2) loss of residual magnetism over long period of no use. can be remedied by "flashing" the shunt field winding howlumf
A series reactor is connected in series with a power system component, such as a transmission line or generator, to limit short-circuit currents and manage voltage drop during load fluctuations. In contrast, a shunt reactor is connected in parallel to the system, primarily used to absorb reactive power, improve voltage stability, and mitigate voltage rise in long transmission lines under light load conditions. Essentially, series reactors focus on current limiting, while shunt reactors focus on reactive power management.
Poems are short and novels are long.
What revolution?
It depends. Most Ventriculoperitoneal ( VP for short) shunts may be implanted for life for the treatment of hydrocephalus ( excessive cerebral spinal fluid, or CSF, build up in the brain ). The type of shunt and the health problem it is treating will ultimately determine the length of implantation.
Connect the circuit as per the circuit diagram shown in fig1. Keep the field regulator of the motor in the minimum resistance position and regulator of the generator in the maximum resistance position.2. Switch on the supply and start the motor with the help of its starter.3. Adjust the field regulator of the motor such that it runs its rated speed given on thename plate.4. Adjust the armature regulator of the generator to build up its rated voltage given on itsname plates on no load.5. Note down the no loads of ammeter and volt meter in tabular form.6. Increase the load gradually in steps and tabulate the readings7. Plot the external characteristics is load current Vs terminal voltage.8 Connect the generator for differentially compounding, repeat the process and plot theexternal characteristics.
that strategy is long term and planning could be a short term.
The main difference between short black and long black coffees is the amount of water used. A short black has a smaller amount of water and is more concentrated, while a long black has more water and is milder in flavor.