The ratio of output windings to input windings determines the ratio of output voltage to input voltage. The ratio of current is the inverse.
Your question reveals a misunderstanding of how a transformer works.The primary current of a transformer is determined by the secondary current, not the other way around. When the secondary voltage is applied to a load, a secondary current flows, and its value is determined by the secondary voltage and the load impedance. This secondary current then determines the value of the primary current.
Output voltage (...of a transformer, for example...) will decrease as it is loaded because of the transformer's internal resistance. As output current increases/load resistance decreases, a larger voltage will be dropped across the internal transformer resistance. This same phenomenon is present in AC and DC systems (such as batteries).
Because the windings of transformers have resistance, the primary and secondary currents will cause voltage drops. To compensate for the drops, the transformer may have been designed to have a higher than specified output voltage when there is little or no output current. The no load output voltage typically is only slightly greater than the specified voltage. Before measuring the output voltage, measure the input (line) voltage. If it is not as specified for the transformer, calculate its effect on the output.
There is no 'standard' output current from a transformer. The secondary (output) current depends on the load, and should not exceed the rated secondary current. To find the rated secondary current, you divide the transformer's rated volt amperes by the rated secondary voltage. The above cited answer need more descriptive ; a) V/Z = I, b) V/Z = I + Magnetizing current of the transformer taken from Primary side of the transformer.
Variable transformer may also refer as auto transformer. We can vary the output voltage of the transformer. But in the ordinary transformers output voltage is already designed.
The secondary (output) voltage is determined by the primary voltage and the turns ratio of the transformer. The secondary current is determined by the secondary voltage and the load resistance.
Your question reveals a misunderstanding of how a transformer works.The primary current of a transformer is determined by the secondary current, not the other way around. When the secondary voltage is applied to a load, a secondary current flows, and its value is determined by the secondary voltage and the load impedance. This secondary current then determines the value of the primary current.
Output voltage (...of a transformer, for example...) will decrease as it is loaded because of the transformer's internal resistance. As output current increases/load resistance decreases, a larger voltage will be dropped across the internal transformer resistance. This same phenomenon is present in AC and DC systems (such as batteries).
Output power can never be more than input power. With a transformer, it is possible to increase the output current (while decreasing the output voltage), or to decrease the output current (while increasing the output voltage).
3
Because the windings of transformers have resistance, the primary and secondary currents will cause voltage drops. To compensate for the drops, the transformer may have been designed to have a higher than specified output voltage when there is little or no output current. The no load output voltage typically is only slightly greater than the specified voltage. Before measuring the output voltage, measure the input (line) voltage. If it is not as specified for the transformer, calculate its effect on the output.
The transformer itself does not pull current. Whatever you connect to the transformer pulls current. Whatever the output voltage of the transformer is, divide that into 600 and you get maximum current possible without burning up the transformer. At 24V that's 25 amps.
yes,we can change the transformer side in transmission line as use of high current or high voltage in output.
There is no 'standard' output current from a transformer. The secondary (output) current depends on the load, and should not exceed the rated secondary current. To find the rated secondary current, you divide the transformer's rated volt amperes by the rated secondary voltage. The above cited answer need more descriptive ; a) V/Z = I, b) V/Z = I + Magnetizing current of the transformer taken from Primary side of the transformer.
The rating is about 1500W. This is for both the input and the output. Output voltage is usually 2,000 volts. Divide watts by input volts to get input current. And divide watts by output voltage to get output current. -Joe
In order to induce voltage as an output, a changing magnetic field is needed. To create a changing magnetic field in the transformer a changing current and that is an alternating current.
Variable transformer may also refer as auto transformer. We can vary the output voltage of the transformer. But in the ordinary transformers output voltage is already designed.