answersLogoWhite

0

It should have a code identifying what kind of fuse it is, which can be looked up.

User Avatar

Wiki User

14y ago

What else can I help you with?

Continue Learning about Engineering

What is the current rating of T2L 250v fuse?

The current rating is 2A (2 amps).


What happens if you use a fuse that's overrated for voltage but has the correct current rating?

Using a fuse correctly rated for current but "overrated" for voltage does not present a problem. Current ratings are critical safety issues, and fuses should be replaced with those of the same current rating. But using a fuse with an identical current rating but a higher voltage rating is not a problem. The reason for that lies in what the voltage rating of a fuse is. Fuses are given a voltage rating to state a maximum voltage in a circuit that they are designed to protect. And the voltage rating has nothing to do with the "normal" operation of the fuse. The fuse carries current when it operates normally, but when something happens and excessive current flows, the fusible link heats up and opens. This is where the voltage rating comes into play. It is possible that a fuse can arc through when it fails. It is the voltage rating that stands in the way of this. As long as the voltage rating of a circuit is not beyond the voltage rating of the fuse, that fuse will fail safely when it fails. It is acceptable to use a fuse of an equal current rating but a higher voltage rating when replacing a fuse that has failed.


How is the minimum fusing current related to the current rating of a fuse?

Each fuse has its own rating. It will be marked on the fuse somewhere.


What is the maximum current that can flow through a fuse?

A current rating of a fuse is designed to open a circuit at a specific current flow. This rating is imprinted on the fuse and lets you know what the maximum amount of current the fuse is designed to open at. A fuse is in the circuit to protect the conductor that the current flows through. Never over fuse a conductor's current carrying capacity.


Why should a fuse of defined rating not be replaced with one with larger rating?

The fuse is rated to protect the equipment, the supply, and you. Change the fuse for a higher rating and you compromise your safety and equipment and supply safety; increasing the risk of electric shock and of fire.

Related Questions

What will happen to an appliance if the fuse rating is less than the current an appliance needed?

If the fuse rating is less than the current an appliance needs, the fuse will likely blow or burn out. This is because the fuse is designed to protect the appliance from overheating or catching fire by interrupting the circuit when the current exceeds the fuse rating. It is important to always use a fuse with a rating that matches the current requirements of the appliance.


Can a 250V 2.5A fuse replace a 125V 2.5A fuse?

Yes, a 250V fuse can replace a 125V fuse if they have the same ampacity rating. The voltage rating is simply the maximum voltage that the fuse is capable of safely interrupting. You can go higher, but you can not go lower. Obviously, the form factor of the fuse must be the same, but that is often the case.


How does a fuse prevent an overlode circuit?

A fuse contains a wire that will melt and break the circuit if too much current flows through it, preventing an overload. When the current exceeds the fuse's rating, the wire melts, interrupting the flow of electricity and protecting the circuit from damage.


Will it work if you replace a 1.25 amp 125 volt fuse with a 1 amp 250 volt fuse?

Yes you can do that as long as it will fit in the fuseholder. It is acceptable to replace a lower Voltage Rated fuse with a higher but NEVER replace a higher with a lower. There are several things to consider when replacing a fuse: 1) The minimum voltage rating of the fuse is equal to or higher than the voltage of the circuit you are placing it in 2) The Amperage rating of the fuse does not exceed the capacity of the circuit you are trying to protect. Always replace a fuse with one that has the same amperage rating. 3) The interrupting rating of the fuse is sufficent for the capacity of the circuit supplying the fuse. If replacing a fuse always use one with an interrupting capacity equal to or greater than the fuse you are replacing.


What does L stand for in a fuse labeled T2AL 250V?

In a fuse labeled T2AL 250V, the "L" stands for "Low breaking capacity." This indicates that the fuse is designed to break the circuit under low fault current conditions. The "T" signifies that it is a time-delay fuse, while "2A" indicates the current rating of the fuse, which is 2 amperes. The "250V" specifies the voltage rating of the fuse.


It is ok to use a fuse with a higher amperage rating and not ok to use a fuse with a smaller amperage rating why?

It is ok to use a fuse with a higher amperage rating and not ok to use a fuse with a smaller amperage rating why?


What is kilo ampere interrupting capacity?

Kilo ampere interrupting capacity (KAIC) refers to the maximum amount of electrical current in kiloamperes that a circuit breaker or fuse can safely interrupt without sustaining damage. It is a key rating to ensure the safety of electrical systems by preventing excessive current from causing equipment failures or electrical fires. The higher the KAIC rating, the better the protection provided by the circuit protection device.


What is the current rating of T2L 250v fuse?

The current rating is 2A (2 amps).


What happens if you use a fuse that's overrated for voltage but has the correct current rating?

Using a fuse correctly rated for current but "overrated" for voltage does not present a problem. Current ratings are critical safety issues, and fuses should be replaced with those of the same current rating. But using a fuse with an identical current rating but a higher voltage rating is not a problem. The reason for that lies in what the voltage rating of a fuse is. Fuses are given a voltage rating to state a maximum voltage in a circuit that they are designed to protect. And the voltage rating has nothing to do with the "normal" operation of the fuse. The fuse carries current when it operates normally, but when something happens and excessive current flows, the fusible link heats up and opens. This is where the voltage rating comes into play. It is possible that a fuse can arc through when it fails. It is the voltage rating that stands in the way of this. As long as the voltage rating of a circuit is not beyond the voltage rating of the fuse, that fuse will fail safely when it fails. It is acceptable to use a fuse of an equal current rating but a higher voltage rating when replacing a fuse that has failed.


What sort of fuse would you select for an installation that required high current interrupting ability and an allowance for instantaneous over currents?

The best type fuse for an installation that required high current interrupting ability and an allowance for instantaneous over currents, would be the largest fuse sufficient for normal use and a relay to another fuse for the over currents. It is always best to consult an electrician.


How is the minimum fusing current related to the current rating of a fuse?

Each fuse has its own rating. It will be marked on the fuse somewhere.


What is meant by ratting of fuse?

A fuse is given a various rating (strength). For instance, a home appliance (washing machine, etc) would usually have a fuse with a 13 amp rating. While a low powered lamp would only merit a 2 or 5 amp fuse rating. It is important to use a fuse of the correct rating in amps for each electrical appliance.