The auxiliary contact is to be utilized for interlocking of another relay or contactor or indication signal from another equipment.


How does magnetic contactor operate?

explain me about the contactor works with examples. if i want to control a motor with contactor. and how i can use contactor in loops with over load and circuit breakers.


How do you calculate contactor capacity of star contactor?

metres


What is the difference between an definite purpose contactor and a lighting sontactor?

A definite purpose contactor is designed (and rated) for a specific load. So a lighting contactor is one example of a definite purpose contactor. A motor starter contactor is another example. So, a lighting contactor is a definite purpose contactor, but a definite purpose contactor is not necessarily a lighting contactor (it might be a motor starter, for instance).


Can you use an AC contactor in the place of DC contactor?

No, you definitely cannot.


Can you replace a 50 amp contactor with a 40 amp contactor?

Replacing a 50 amp contactor with a 40 amp contactor is not advisable, as the 40 amp contactor may not be able to handle the load safely. This could lead to overheating, failure of the contactor, or potential damage to the connected equipment. It's essential to match the contactor's rating to the load requirements for safe and reliable operation. Always consult with a qualified electrician for such replacements.


Definition of coil in contactor?

The coil in a "Contactor" is essentially an electromagnetic coil that provides the driving force to close the contacts in a Contactor. When the "Coil" is energized by a lower control voltage usually from some type of controller such as a PLC, the Normally-Open contactor will close or in the oposite case, the Normally-Closed contactor will open.


How is a Blowout coil connected?

A blowout coil connected in series with contactor's auxiliary contacts that shunt around the main contactor contacts. The coil is out of the circuit when the main contactor contacts are closed and in the circuit when the main contactor contacts are open.


Is slate interlocking?

Slate tiles can be interlocking or non-interlocking. Interlocking slate tiles have a system that allows them to fit together tightly, creating a seamless look. Non-interlocking slate tiles are simply butted up against each other without any interlocking mechanism.


How many wires to control a mechanically held contactor?

A contactor is a type of switch. However this switch uses electricity to power an electromagnetic coil to switch on or off power. Hence a contactor needs 2 wires - A live/hot wire and a neutral wire. Generally these are connected across the A1 and A2 terminals of the contactor.


If you have a bad compressor does that mean you need a new contactor?

Not always. But if a compressor goes bad it can take out the contactor. I have replaced compressors before and found the contactor is still ok. In a commercial application Copeland will not honor the warranty if the contactor is not replaced at the same time a new compressor is installed. Not sure about residential but for a $15 contactor I would not gamble with it.


What are contain in contactor?

contactor is a device for making and breaking current. it just behaves like a socket.