1" Duct Board has an R-Value of 4.3
Fiberglass Insulation, R Value of 3.14. Pine board has an R Value of 1.74
Meghan R. and Natalie D.
Where does the R value, respiratory quotient or RER come from.
The value of resistance ( R ) in ohms (Ω) can be determined using Ohm's Law, which states that ( V = I \times R ), where ( V ) is voltage in volts and ( I ) is current in amperes. To find ( R ), you can rearrange the formula to ( R = \frac{V}{I} ). Thus, the specific value of ( R ) depends on the given voltage and current in a particular circuit.
Fiberglass Duct Board is cheaper to install than Sheet Metal Ducts. This is definitely the choice of most builders if you don't know any better. Your Air Distribution Duct System should look like a tree ... comprised of a Main Trunk and Branch lines from that trunk. The trunk should bet smaller as it passes every several branches in order to maintain the pressure. Each branch line should have a manual damper (valve) to regulate the volume for balancing. Then you can eliminate hot and cold spots. All joints should be sealed with mastic and UL 181 rated tape. The biggest problem is that while it may look good, its structure gets less rigid (spongy) and interior lining is disgusting after just a few years of normal use. It's literally falling apart after 5 years. Almost every client of mine whose home has a duct board (did I say cheap) system complains of allergies and excessive dust. The only benefit is that when you finally decide to install a safer, more reliable, once-in-a-lifetime metal system, the duct board system can usually be removed in less than an hour with just a knife. Then it is placed in trash bags to remove it from the house without getting airborne particles everywhere. The only good use is when you want to line a return (with the foil side facing you) for additional insulation purposes. The only thing worse than ductboard is a duct system made of Flexible main trunks connected to small duct board triangles being used for sub-distribution into smaller areas.Whoever dreamed that one up was really looking to rip you off. mrgeothermal.com
The R-value of a 2-inch foam board is typically around R-10 to R-12.
Fiberglass Insulation, R Value of 3.14. Pine board has an R Value of 1.74
The R-value of 2-inch foam board is typically around R-10 to R-12, indicating its insulation effectiveness.
Drywall provides an R-value of 0.32 for 3/8" board, 0.45 for 1/2" board, 0.56 for 5/8" and 0.83 for 1" board. In addition to increased R-value, thicker drywall has a higher STC.
The R-value of 2 for foam board indicates its ability to resist heat flow. A higher R-value means better insulation, so a foam board with an R-value of 2 provides moderate insulation against heat transfer.
No, you should not use a humidifier in a main trunk line that is made out of duct board. This will cause the duct board to rot from the moist.
what r the advantages of side view of duct ? why we plot side view of duct ?
I assume you mean 2 inch thick foam sound board??? The answer lies in what type of foam specifically you are speaking of.Polyisocyanurate foam has an rvalue of approx. r-7 per inch,being one of the higher r value foams readily available in 4'x8' sheet size.Polystyrene foam board,commonly found in building centers and home centers,and commonly referred to as "Dow" board has an r value of approx. r-5 per inch.To calculate the 2" thickness you reference,simply double the r value given(r value is generally stated as "r value per inch".Thus ,2" polystyrene has an r value of r-10 (r-5/inch x 2).These are fairly general guidelines,and depending on your application,you may want to find more detailed specifications that speak to degradation of R value over time,properties and characteristics of various foam types,etc,etc.
The R value of poster board is about 1.3. Really it is about 1.2783 but I assume 1.3 will be close enough. good luck for whatever you need it for!
The r value of foam board is significant in determining its insulation effectiveness because it measures the material's ability to resist heat flow. A higher r value indicates better insulation properties, meaning the foam board can better keep heat from escaping or entering a building, leading to improved energy efficiency.
The R-value of a 1-inch thick pine board is approximately 1.41. This value can vary slightly depending on the specific species of pine and its moisture content. R-value measures thermal resistance, with higher values indicating better insulating properties. For effective insulation, pine boards are often used in combination with other materials.
why we plot side view of a duct?