Both conductors are at ground potential. They are connected together with a bonding jumper at the panel. The primary difference is the neutral is used as the return current path for single-phase loads, and the ground is the return path for fault current only. So, unless the hot conductor accidentally comes in contact with, say, a grounded equipment cabinet, there would be no current flow on the ground wire. The neutral wire carries current any time the single-phase load is in operation. With a three-phase balanced load, no neutral is necessary or required, yet electrical codes still require a ground wire for safety.

User Avatar

Wiki User

16y ago

What else can I help you with?

Related Questions

What is the difference between air gap and air break in plumbing?

water distribution system ===


How do you size the neutral in a 240 volt system?

On a 120/240 volt distribution the neutral is sized along with the supply conductors. The sizing is based on the amperage of the service distribution.


What is the difference between neutral point and earthing?

Earthing point is where conductor is directly connected to ground and its potential is always zero. Neutral is a return path in single phase system and in three phase system Neutral point will have zero potential if all the loads are balanced in the system. In un balanced three phase system even neutral point will have some potential


What is non-effectively grounded distribution system?

A non-effectively grounded distribution system is one in which the neutral point of the system is not connected to ground or is inadequately grounded. This can lead to issues such as high voltages on the neutral wire, increased risk of electrical shocks, and difficulty in fault detection and protection. Proper grounding is essential for ensuring the safety and reliability of the electrical distribution system.


When does a motor not need a neutral wire?

If the motor is operated from a three phase three wire distribution system the motor will not need a neutral wire.


What is the phase difference between in two voltage phases in 3 phase distribution system?

The phase difference between any two live lines is 120 degrees, which allows them to peak in turn in the 360-degree cycle.


Difference between system software and operating system?

difference between operating system and system software?


What is the difference between cropping system and farming system?

difference between farming system and cropping system


What is rod earthing?

It is the installation of ground rods at a service entrance distribution to bring the relative resistance to ground to be within 5 ohms of the utility's distribution network. This grounding system is then connected to the service distribution with a calculated size wire and connected to the distribution at a point within the distribution panel, where the service neutral wire joins the neutral bus bar.


Should there be voltage between the neutral and ground?

No, ideally there should be no voltage between the neutral and ground wires in an electrical system.


Is neutral connected to earth in main panel?

Answer for USA, Canada and countries running a 60 Hertz supply service.Yes, the neutral is connected to a system ground in the main distribution panel.


What is the reading ground to neutral?

Ideally ground and neutral should be at the same potential, but as there is current in the neutral wire and no current (normally) in the ground wire there can be a difference. I have personally measured over 25 VAC on the neutral relative to ground in some systems.