You shouldn't need to perform a polarity test on a CT, as its terminals are normally identified with polarity markings.
The stability and sensitivity test shall be performed for unit protection to prove the stability for through fault and sensitivity for the internal faults. The principle of the test is as followed. The protected zone of unit protection is restricted by location of the CTs. For stability test the primary current shall be injected through one set of two CTs such a way one of current inwards and other outwards. At relay terminal no operating current shall be observed for proper connection. Sensitivity test shall be conducted with same set-up with either reversed CT polarity or injecting primary current on only one CT of the set. At relay terminal, operating current shall be observed for proper function.
The net measured power would appear to be negative, or reversed.
The megger test on a generator is usually done to check the insulation factor of a generator. The high voltage is usually used to test the insulation system of a the generator in question. It is recommended to do this test after every six months.
You are probably referring to a 'polarity mark'. This is very important if the CT's burden requires current to flow through it in a particular direction in order to work properly. For example, it won't make any difference if the burden's an ammeter. But if the burden is, say, a wattmeter, then it's very important to observe the CT's polarity mark when it is wired, otherwise the wattmeter might read 'downscale' (backwards). It's also very important when the CT supplies protection relays.
Basic Required Functionality Backup Functionality Required Signalling Schemes Available communication. Supply (AC or DC?) Operating Voltage on Inputs. CT input 1A 5A or other? How many CT inputs (Will it be used in Breaker and a Half arrangement) Do you require one or 2 VT input. Do you need sub cycle operation.
On the CT there will be a white dot that represents a polarity mark. This is used to connect to the correct polarity terminal on the device that the CT is connected to. Additional CT transformers must be connected to the recording or monitoring device using the same polarity as the first CT.
testing polarity of CT by Flick test . A centre zero voltmeter is connected across CT secondary .A 1.5V battery is touched to primary of CT .the deflecting of pointer should be similar in case of each CT to be connected in same protection .
I will assume that your question is in reference to CT and transformer polarity.In the case of a CT (Current Transformer) they have to be installed in the correct direction for proper metering. The polarity check is used to verify that they are installed correctly and that the polarity marks are correct (if the CT has them).In the case of a transformer there are two types of polarity, additive and subtractive. If you are paralleling transformers you have to ensure that they are the same type polarity in addition to other attributes.Hope this helps.Alternative AnswerIn a new electrical installation, a polarity test is conducted to ensure that socket outlet terminals are correctly wired (line really is line, neutral really is neutral, and the protective conductor (earth/ground) really is protective conductor. It's also important, for example, that the centre pin on an Edison Screw lampholder is connected to line, and not to neutral.
ct ratio test is the current between the primary to secondary
The stability and sensitivity test shall be performed for unit protection to prove the stability for through fault and sensitivity for the internal faults. The principle of the test is as followed. The protected zone of unit protection is restricted by location of the CTs. For stability test the primary current shall be injected through one set of two CTs such a way one of current inwards and other outwards. At relay terminal no operating current shall be observed for proper connection. Sensitivity test shall be conducted with same set-up with either reversed CT polarity or injecting primary current on only one CT of the set. At relay terminal, operating current shall be observed for proper function.
see http://ezinearticles.com/?Testing-a-Transformer--How-To-Accurately-Test-A-Transformer&id=56803 Normally to test a CT we go on with two tests 1. the primary injection test 2. the polarity test 1. primary injection test: a particular amount of current is made to flow through the primary and the amount of current we get from secondary is measured. 2. the name itself describes the test...