answersLogoWhite

0

The primary line side of a 3 phase transformer should be marked H1, H2, H3. The line side is the incoming voltage that you want to step up or step down or isolate.

User Avatar

Wiki User

14y ago

What else can I help you with?

Continue Learning about Engineering

What is the fuse rating in HT side of 11.4kv500kva transformer?

You need to specify the phase. I assume it is 3 phase system. Then the HT current is 30.3 amps


How you differentiate between single phase and three phase transformer?

A single-phase transformer works with a single-phase supply, while a 3-phase transformer is used with a 3-phase supply. A single-phase transformer has 2 wires on the primary and secondary (ignoring taps) while a 3-phase tansformer has 3 or 4 wires on the primary and secondary.


Is possible to put 3 phase transformer primary as secondary and secondary as primary?

A: The only way can be possible if the transformer is an isolation type. Yes, you can put the input into the secondary side. This will create a step-up transformer.


Why there is a phase shift of 30degree in Dyn11 3 phase transformer?

The phase shift is caused by inductance in the transformer. Any inductance from magnetic flux that fails to link both windings is called leakage flux, and the resulting inductance is called leakage inductance.


How many amps can 30 kva transformer 575 volts to 480 volts gives?

for three phase the calculation is 30,000 = 1.73*V*I - simple as that. For single Phase the calculation is 30,000 = V*I - simple as that It is important to note the voltage in the first line is Line to Line (typically how it is specified in three phase power systems), and the second line it is Line to neutral. A 30KVA transformer is the same as 30,000VA to find out the Amps you need to divide the voltage if the transformer is single phase for example: 30,000VA / 480V = 62.5 Amps The calculation for a 3 phase transformer is the VA / voltage / 1.73 for example: 30,000VA /480V / 1.73 = 36.12 Amps

Related Questions

How do you get 380 volt from 220 3 phase?

Only with a 3 phase transformer.


What is the fuse rating in HT side of 11.4kv500kva transformer?

You need to specify the phase. I assume it is 3 phase system. Then the HT current is 30.3 amps


How many bushing do you get on delta to star transformer?

Your use of the word "bushings" implies you are dealing with a high-voltage transformer (over 600 volt). A three phase STEP-DOWN transformer normally has 3 bushings on the Primary side regardless of whether it is star-delta or another type. The Secondary side might have 3 or 4. A single phase transformer normally has 2 bushings on the Primary side and 2 or 3 on the Secondary side. If the transformer is being used to STEP-UP, it would be reversed from above. If this does not answer your question, I need more info.


How do you convert a 3-phase system to a single phase?

By having a transformer with 3 phase input and single phase out put


Difference between line transformation ratio and transformation phase ratio?

line transformation ratio would be the turns ratio (ie voltage ratio), while the phase transformation ratio is most probably the phase shift introduced by a 3 phase transformer.


How you differentiate between single phase and three phase transformer?

A single-phase transformer works with a single-phase supply, while a 3-phase transformer is used with a 3-phase supply. A single-phase transformer has 2 wires on the primary and secondary (ignoring taps) while a 3-phase tansformer has 3 or 4 wires on the primary and secondary.


Is possible to put 3 phase transformer primary as secondary and secondary as primary?

A: The only way can be possible if the transformer is an isolation type. Yes, you can put the input into the secondary side. This will create a step-up transformer.


What are the advantages of 3-phase transformer over 3 single-phase banks of transformers?

The main advantage is that the 'footprint' of a three-phase transformer is smaller than a transformer bank, and all connections are prewired which makes them easier and quicker to install and replace.


Why there is a phase shift of 30degree in Dyn11 3 phase transformer?

The phase shift is caused by inductance in the transformer. Any inductance from magnetic flux that fails to link both windings is called leakage flux, and the resulting inductance is called leakage inductance.


How do you calculate amperage of a 3 phase transformer?

Total KVA of the transformer divided by (square root of 3 times the voltage). This will give the individual phase currents. These individual phase currents will be 120 degrees out of phase with each other.


How many amps do you need to supply a 150kva transformer to get 118amps 480 volts?

Rephrase your question, as it doesn't make any sense. If the primary side of the transformer is 480 volts 3 phase, this transformer can be supplied from a breaker as big as 180 amps. If 480 volts 3 phase is your secondary then you can supply up to 180 amps to your loads.


Basic operation of a 3-phase transformer?

Three Phase transformers have three windings. If connected in Delta, it will have R Y B phase winding, voltage between RY, YB and BR. Phase voltage and line voltage are same. If connected in Star, there will be a neutral as well with RYB. Line voltage and Phase voltage are different. Line voltage = 1.73 x Phase voltage.