The power loss in aluminum 33kV line conductors primarily occurs due to the resistance of the conductor, which leads to I²R losses, where I is the current and R is the resistance. The amount of power loss can be calculated using the formula P_loss = I² × R. Aluminum conductors have a relatively lower conductivity compared to copper, which can result in higher losses for the same current. However, the actual power loss will depend on factors such as the length of the line, the current flowing through it, and the temperature of the conductors.

User Avatar

AnswerBot

2w ago

What else can I help you with?

Related Questions

What are the effects of being at end of 33KV transmission line?

The effects of being at the end of a 33KV transmission line will result in a higher voltage. This is due to variation in the perameters that dictate how the transmission is sent and received.


What ACSR conductor is used for 33kV transmission line?

Single Circuit PantherACSR Conductor


Why you transpose the conductors?

Transposing the conductors in a power line reduces electromagnetic interference and power loss. By regularly changing the position of the conductors, electromagnetic fields cancel each other out, leading to improved power transmission efficiency and reduced interference with communication lines.


How do you tell the difference from 13.2 kv power line to 4.8 kv power line?

The higher-voltage line will have longer insulators and the line conductors will be further apart. And the symbol for kilovolt is 'kV', not 'kv'.


What are the advantage of stranded conductor over solid conductors in a transmission line?

In a transmission line, voltage is stepped up to a very high value. This is so as to take advantage of lower line current and smaller conductor size. At these potentials1, however, like charges repel, so most of the current flow is along the skin of the conductor. Stranded conductors, even wound wire over insulating rope, is more efficient, and more cost effective, than solid conductors.--------------------------------------------------------------------------------------------------1 Actually, this effect occurs at any voltage, but it is most notable at the very high voltages used in power line transmission systems.AnswerStranded conductors are used because of their flexibility compared with solid conductors. Normally, transmission lines consist of a steel-wire core (which provides strength) around which are wound stranded aluminium conductors.


Why only 11kv is used in power systems transmission line?

It isn't. In the UK, transmission and distribution voltages are 400 kV, 275 kV, 132 kV, 66 kV, 33kV, and 11 kV.


How much power can a transmission line carry?

700 Billion voltsAnswerFirst of all, power is expressed in watts, not in volts! Your answer cannot be answered in any straightforward way, because it depends upon too many variables. For example: At what voltage is the transmission line operating? What is the current-rating of its conductors? How many conductors comprise each line? Etc.


How many conductors does a POTS line use?

Each telephone line uses only two conductors.


What is Indian railway transmission line voltage?

220v, 415v, 6.6 kv, 11kv,33kv,132kv,400kv


What are the components used for trnsmission lines?

There are no component is used in transmission line . the used things are- conductors for transmitting power to one place to another place. insulator for separate these conductors and some other basic things are required necessary for net of transmission line.


Hollow conductors in transmission line used to?

To reduce skin effect.CommentHollow conductors are not used on electricity transmission lines. Transmission-line conductors are normally manufactured of stranded aluminium conductors, wound around a steel-wire core. The steel core improves the conductor's tensile strength.Hollow conductors are, though, used as 'wave guides' in radio-frequency circuits. However, their purpose is not to reduce skin effect (in which most of the current flows close to the surface of the conductor), but to save copper -if most of the current flows close to the surface, then there's little point in using solid copper!AnswerHollow conductors are used on very high voltage underground cables, which are cooled by passing oil or gas through the conductors.


How the voltage regulation in 33kv line?

It does not depend on the line. The regulation is the percentage change in voltage caused by applying the full load current, and that depends on the transformer supplying the line. A value of 5% would be typical.