Is any voltage drop over a 200 meter overhead cable if you have a 440 three phase system?

There is voltage drop over any sysetm that does not have infinitely low resistance, but with reasonable cable size there would be very little drop over 200 metres. The number of phases makes little difference.


What AWG cable for 200' x 208 volt three phase 250 amp circuit?

A wire size of 250 MCM will limit the voltage drop to 3% over a distance of 200 feet.


What is the length of a large ocean freighter?

200/300 mtrs.


What is the correct wire size to install with a distance of 200 feet for a 100 amp single phase underground service?

This is a voltage drop question. A #1 copper conductor will limit the voltage drop to 3% or less when supplying 100 amps for 200 feet on a 240 volt system. Or a 3/0 copper conductor will limit the voltage drop to 3% or less when supplying 100 amps for 200 feet on a 120 volt system. In your question you sis not stipulate what the working voltage is.


Would using a 200 foot extension cord which is 6 gauge 3 wire cord on a 220 single phase welder present any problems?

Absolutely, you will have voltage drop, maybe enough voltage drop that the welder will not work <<>> To do a voltage drop calculation for the 200 foot cable the input amperage of the welder needs to be stated. At a maximum distance of 201 feet and limiting the voltage drop to 3% or less, a #6 copper conductor can deliver 37 amps on a 220 volt system. Check the nameplate on the welder to see if it falls withing the range of 37 amps input amperage. Do not use the welders output amperage.


What gauge wire is needed to run 200 feet and carry 30amps?

This is a voltage drop question. To answer this question a voltage must be stated.


What size wire do you need to run 200 ft of 125 amp?

This is a voltage drop question. To give an answer the voltage must be stated.


What size wires are used in the construction of the 200 amp low voltage cable?

4/0


What is the water level in jamshedpur city?

200 mtrs above see level


What gauge wire do you need to run 75 amps at 200 ft away?

This is a voltage drop question. To answer this question a voltage must be stated.


What size wire for a 200 amp 3phase service 100 feet away?

This is a voltage drop question. A voltage must be stated to answer this question.


What wire size will carry 50 amps 200 ft 110 voltage?

Because of voltage drop, 4 awg copper would be recommended for that distance run. <<>> A #1 copper conductor will limit the voltage drop to 3% or less when supplying 50 amps for 200 feet on a 110 volt system.