Related Questions

How do you figure kw in a three phase system?

The watt meter on three phase system is the same as the one on your house except that it monitors all three phases at once. The meter base is called a 7 jaw base which monitors the three phases and the neutral. The house meter is a 5 jaw meter. The watt meter is a totalizer which keeps track to the watts consumed by the dials on the face of the meter, which gets read monthly by the power supplier.


Why three phase meter is better than single phase meter?

A three-phase meter can be used for single phase while the reverse is not the case.


What is conversion of 4.6kva to kw?

Single-phase, 2.5 amps; three-phase 1.443 amps.


Can you use single phase kwh meter for three phase load?

No, a single phase kWh meter is designed to measure the energy consumption of single phase loads only. To measure the energy consumption of a three phase load, you would need a three phase kWh meter specifically designed for that purpose. Using a single phase meter for a three phase load would not provide accurate energy consumption readings.


What is the equations to get KW of a generator?

The formulas you are looking for are, single phase kW = I x E x pf/1000. For three phase kW = I x E x 1.73 x pf/1000.


Is it possible to convert a 2.4 kw single phase appliance to a 9kw 3 phase appliance?

No, it is not possible to convert a 2.4 kw single phase appliance to a 9kw 3 phase appliance. Single phase can not be converted to three phase with out considerable cost involved.


What is the difference between single phase and three phase voltage measurement?

Phasing, or the number of phases in an electrical system has nothing to do with the voltage. A single phase and three phase supply could have a voltage supply of any given voltage from virtually 0 to infinity. Most single phase power supplies in the US are 120/208-240 volt. Three phase power supplies are typically 120/208 to 277/480 volt.


What is the kw input on a 50amp breaker with a 208v three phase electrical feed?

7200


Reverse running of three phase meter?

The reverse running of a three phase meter is possible when one of the meter's two potential coils fails. This is a problem found typically on a Delta service. A three phase meter in this condition is damaged and will report lower energy use than actual.


What kind of electrical savings can be expected between a 3 phase convection oven and a single phase?

Virtually nothing. The only real benefit you would get is if you had three phase vs. single phase fans, and I'm fairly certain even the three phase convection ovens use single phase fans. The oven will be rated at a certain kW usage, which applies whether it's three phase or single phase (...and will be ~ the same). If the three phase convection oven kW usage is slightly lower, it is because it is heating slightly less (so its' kW rating is actually less than the single phase), and vice versa. Insulating factors will have a significantly higher impact on cost savings compared to single vs. three phase in this instance.


What is kilowatt of 10k at 208volts?

The formula you are looking for is kW = I x E x pf/1000 for single phase and kW = I x E x 1.73 x pf/1000 for three phase.


How would a three phase meter reading compare to three single phase meters connected to the same service?

The reading on the 3-ph meter would equal the sum of the three separate readings on the single-phase meters. The neutral sides of the single phase meters do not need to be connected to the neutral wire as long as they are connected together.