refer to
http://yourelectrichome.blogspot.com/2011/03/circuit-breaker-time-total-break-time.html
I think that the questioner is asking what is the difference between an isolator and a circuit breaker.A circuit breaker is a switching device designed to interrupt a fault current.An isolator is not intended to break a live circuit but, rather, to provide a visible separation between a circuit component and live conductors.For example, isolators (or 'disconnectors' in US parlance) are located on either side of a high-voltage circuit breaker. If the circuit breaker requires maintenance, then the procedure is to:a. trip the circuit breaker.b. open the isolators on each side of the circuit breaker, so there is a visible gap between the circuit breaker and the 'hot' conductors.c. apply temporary earths (grounds) between each isolator and the circuit breaker.d. complete a 'permit to work' card.e. begin work.
A fuse is used one time and replaced. A breaker can be re-set.
Answer for countries in Europe and other world areas running a 50 Hz supply service.Depending on the load of your lighting circuit. I would measure the current with an inductive amp meter. once you know the current required for your lighting circuit, you then install a circuit breaker which is 15% higher than your load. eg, load is 10A. 10A load + 15 % = 12A breaker (15 A is ok as the breaker is used to protect the wiring and should be rated in consequence of your wiring by 25% less or its current rating, or less, not the load)The humming of your lighting circuit breaker indicates that your breaker is either faulty, or having a difficult time keeping a closed circuit. Or simply that the manufacturer produced a breaker that hums by nature of its construction.
There are several type of circuit breakers now a day we are using these are as follows: 1. M.C.B. (Miniature circuit Breaker) Rating : 1, 2, 4, 6, 10, 16, 20, 25, 32, 63 Amperes 2. M.C.C.B. (Miniature current circuit Breaker) Rating : 10, 16, 20, 25, 32, 63, 100, 200, 250, 400 Amperes. 3. A.C.B. (Air Circuit Breaker) Rating : 400, 800, 1000, 1200, 1500, 1800, 2000 Amperes. 4. A. B. Switch (Air Breaker) used in High tension line. 5. SF6 Breaker (Contact break in the Sf6 medium) used in High tension line.
You probably popped the breaker. The appliance is drawing too much current for that circuit (or is combined with too many other appliances on that circuit). Unplug it, turn the breaker back on. Try to find a different circuit to operate it on, or move other appliances to other circuits to reduce the load. If you own your residence you might be able to hire an electrician to completely rewire that circuit with larger capacity wire and breaker and changing the outlets also. This will get expensive though. I cannot use my microwave cooker and my stand mixer at the same time, together they will trip the breaker for the kitchen outlets, but one at a time is OK. It might also be an earth fault in the appliance - As stated turn off other appliances on the same circuit (that should cancel out any over load) and test again . If the breaker drops then the appliance is the issue
A circuit break will reset until it mechanically breaks down. What you should be looking at is why is the breaker tripping all the time. A breaker is a safety device that stop current from overloading the wire that it is protecting. When the breaker trips check and find out what other devices have stopped working. Total up the wattages. If the total is above 1500 watts then something is going to have to be disconnected on that circuit.
A circuit breaker is a switching device which can make,brake and carrying (or trip the circuit) that specified over currents for a small interval of time . There is a different types of Circuit Breaker's are there 1.According to their arc quenching media these are divided into 4 types a) Oil circuit breaker b) Air blast circuit breaker c) SF6 circuit breaker d) vacuum circuit breaker 2. According to their services the circuit breaker can be divided as a) Outdoor Circuit Breaker b) Indoor Breaker 3. According to the operating mechanism of circuit breaker they can be divided as a) Spring operated Circuit Breaker b) Pneumatic Circuit Breaker c) Hydrolic Circuit Breaker 4. According to the voltage level of installation these are divided into 3 types a) High Voltage Circuit Breaker b) Medium Voltage Circuit Breaker c) Low Voltage Circuit Breaker.
I think that the questioner is asking what is the difference between an isolator and a circuit breaker.A circuit breaker is a switching device designed to interrupt a fault current.An isolator is not intended to break a live circuit but, rather, to provide a visible separation between a circuit component and live conductors.For example, isolators (or 'disconnectors' in US parlance) are located on either side of a high-voltage circuit breaker. If the circuit breaker requires maintenance, then the procedure is to:a. trip the circuit breaker.b. open the isolators on each side of the circuit breaker, so there is a visible gap between the circuit breaker and the 'hot' conductors.c. apply temporary earths (grounds) between each isolator and the circuit breaker.d. complete a 'permit to work' card.e. begin work.
A fuse is used one time and replaced. A breaker can be re-set.
It is the relationship between current and time on a circuit breakers opening. When the circuit breaker needs to open in given "windows" of amps and time. They should intersect on the curve to indicate proper circuit breaker functioning. The timing and current value should coincide with each other, per manufacturers specifications. Each breaker differs.
Check the wire that goes to your break light. Somewhere along the circuit it is grounded before the lamp and after the switch. Look on the circuit from the switch to the lamp. What is happening is, the circuit is good up to the time that you apply the break. This closes that brake light switch, When the switch closes it sees the dead short and not the lamp. The breaker popping is protecting the circuit wiring from burning up.
Recently a new technology "solid state' are applied to traditional circuit breaker. This technology has resulted in freeing circuit breaker from arcing and switch bounce, also offering higher reliability and longer lifetimes and a faster switching time.
You should check that you are not running too many appliances on the circuit that is protected by the circuit breaker.If you are absolutely sure that the circuit is not being overloaded, you should replace the breaker with a new identical breaker. Breakers get hot when they supply power at near peak amperage over a long period of time and begin to break down internally.As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.Before you do any work yourself,on electrical circuits, equipment or appliances,always use a test meter to ensure the circuit is, in fact, de-energized.IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.
"T1" in electricity typically refers to a type of circuit breaker. It is a designation used to classify the time delay characteristics of the circuit breaker. T1 circuit breakers are designed to trip within a certain time frame when a fault or overload is detected in the electrical system.
Breaker trip curves show the relationship between the amount of current flowing through a circuit and the time it takes for the circuit breaker to trip. The characteristics of these curves, such as the trip time and current rating, determine how quickly the breaker will disconnect the circuit in case of an overload or short circuit. This impacts the operation of electrical circuits by providing protection against damage from excessive current, ensuring safety and preventing fires.
The load exceeds the limit of the breaker or fuse. For example a 20 amp breaker on a 120 volt circuit will handle 2400 watts. Exceed that wattage and the breaker will trip or the fuse will blow.
The purpose of a circuit breaker is to open the circuit in the event of an overload. Wires/conductors are only rated for a specific Amperage. If this amperage is exceeded the conductor/wire begins to heat up and given enough time it becomes a fire hazard. For instance a 15 amp breaker will trip once the Amps drawn through that circuit exceed 15 amps. The short answer is to keep you safe.