answersLogoWhite

0

Type L or Type K rolls of copper. This has no connections underground so there will be no leaks. You should definitely sleeve the copper with plastic!

User Avatar

Wiki User

16y ago

What else can I help you with?

Continue Learning about Engineering

How do you run a underground water pipe to your garage?

run around in a cicle for an hour then shout at the top of your voice Poogle ming atobismDig a trench to be below the frost line, place sand or clean fill below and above the pipe (Copper Type K) back fill after testing tamper to make sure the soil is properly tampered. place a valve on both sides of the piping


How can you flush clean existing copper water lines?

== Answer== Let water run from every fixture for about 10 min. this should do it.


Does the National Electrical Code allow aluminum conductors to be used for underground installation?

You should be able to search the NEC on the internet. However, local code may play a role in whether or not you can use aluminum in an underground application. The other consideration would be whether or not it's listed as a `direct burial wire`, which is to say, is the insulation manufactured to be buried underground. I'm not a big fan of aluminum, and if you're trying to save some money now, you'll most likely end up having to replace it within 5- 10 years. There's also been a lot of house fires attributed to aluminum wiring as it tends to overheat easier than copper. So search the code on the internet, search your local codes and then go with copper direct burial cable anyway. You'll be happier in the long run. But yes, local amendments notwithstanding, the standard NEC does allow aluminum conductors with the proper insulation rating to be used underground. If it is installed in an underground raceway, it must be listed for wet locations, or for direct burial if buried.


What wire size is needed for 30 amp load for 200 feet?

The minimum wire size for a 30 amp load is 10 gauge copper or 8 gauge aluminum. Assuming a 120VAC circuit and to maintain a maximum 3 percent voltage drop from load to panel, upsizing to 4AWG wiring would be the best selection for this circuit. <<>> An accurate answer can not be given because the type of system has to be stated. Single phase or three phase and a voltage also has to be stated to be used in the calculation for sizing of the conductor. A #8 copper conductor will limit the voltage drop to 3% or less when supplying 30 amps for 150 feet on a 120 volt system.


What is the run time on a charge on Black and Decker trimmer model cst 1100?

I've had mine for over a year, I typically get between 30-40 minutes of run time.

Related Questions

What type of armour cable to you need to run underground to your garage?

Armoured cable is not rated for underground installations. You have to use a cable with a designation for direct burial or wet and damp locations.


How do you run a underground water pipe to your garage?

run around in a cicle for an hour then shout at the top of your voice Poogle ming atobismDig a trench to be below the frost line, place sand or clean fill below and above the pipe (Copper Type K) back fill after testing tamper to make sure the soil is properly tampered. place a valve on both sides of the piping


Will electricity run thru brass?

Yes, electricity can run through brass because it is a conductive alloy primarily made of copper and zinc. The presence of copper in brass allows it to conduct electrical current, though it is not as conductive as pure copper. Brass is often used in electrical applications where corrosion resistance is also a factor. However, for optimal conductivity, materials like copper or aluminum are typically preferred.


Does the London underground run on a Sunday?

Yes.


How many underground tubes are totally underground in London?

45% of the overall network is underground. Nearly all of the lines run underground through the city centre and overground in the suburbs. The busiest stations tend to the be the ones which are completely underground. The Victoria Line is the only line which is completely underground (with the exception of the train depot at Northumberland Park). All the others run partly underground.


Does the Underground Railroad run through North Carolina?

yes, North Carolina was part of the underground railroad.


How did the underground railroad run?

It ran from 1780 to 1862


Can 14-2 wire on a patio post be covered with white conduit?

Yes, that is fine as long as the wire does not run underground. If it does run underground you need 14-2U wire.


What gauge wire for 220v 60a underground run of 260 feet ocation South Georgia?

A #2 copper conductor will limit the voltage drop to 3% or less when supplying 60 amps for 260 feet on a 220 volt system.


Can helium run through copper pipe?

No, helium can escape through the microscopic pores in copper pipe due to its small molecular size. It is not an effective choice for helium containment. Stainless steel or specialized materials are typically used for helium gas containment.


Should you use flex copper to run new hot and cold water line?

Nope Id use type L straight tubing with soldered joints


What service lines are required to be run underground for at least 50 feet before entering an ordnance structure?

Service lines that are typically required to be run underground for at least 50 feet before entering an ordinance structure include electrical, water, and gas lines. This is to ensure safety and minimize the risk of explosions or hazards associated with these utilities in sensitive areas. Specific regulations may vary based on local codes and the type of ordinance structure. Always refer to applicable guidelines and standards for compliance.