when relief valve fails open the system will have nopressure resulting in weak hydraulic operation and if it fails closed( that is the relief valve stuck closed) itwill result in very high system pressure resulting in a very high load on the pump and the enginerunning or driving it.
Muawiah Itum
First, you will need very high voltage to run them altogether. Second, short circuit will be extremely hazardous in your house due to high voltage. Thirdly, you can't switch off the light without off the heater or air conditioning.
Yes. Open circuit. A: It depends on the failure type a short will not necessarily make an open circuit but rather a non functional circuit.
The whole circuit fails - because the action of the bulb blowing cuts the circuit.
Adding more lamps in parallel (across) a line will cause total current to climb. It will keep climbing (increasing) until a load protection device (circuit breaker or fuse) breaks the circuit or until something fails because of excessive current.
If one light bulb in a series circuit fails, all the other light bulbs will go out, until the failed bulb is replaced and the series circuit is completed again.If one light bulb in a parallel circuit fails, all the other light bulbs will still work.
First, you will need very high voltage to run them altogether. Second, short circuit will be extremely hazardous in your house due to high voltage. Thirdly, you can't switch off the light without off the heater or air conditioning.
You should replace the surge strip if the circuit breaker fails to reset.
Yes. Open circuit. A: It depends on the failure type a short will not necessarily make an open circuit but rather a non functional circuit.
If a component of a parallel circuit fails, there are complete pathways for electricity to allow the remaining components to carry on functioning. ( For instance if the living room light bulb fails, the kitchen light can still work.) Also, if you link several bulbs in series, the current through them drops and they are dimmer than one on its own, but this doesn't happen with a parallel circuit.
A relay race would be an example of a series circuit. Since every runner relies on the runner before him/her to continue on, if one runner fails the rest of them fail. With a series circuit, if one part of the circuit fails, all of the parts before and after it fails. A parallel circuit does not completely fail if one or more of the parts fail.
The disadvantage of a parallel circuit is that if one component fails, the other components will still work, making it harder to identify the faulty component. In a series circuit, if one component fails, it breaks the circuit and all components will stop working.
No. Series circuit has 1 path to flow.
The whole circuit fails - because the action of the bulb blowing cuts the circuit.
Both are same. Only thing it depends upon the incoming voltage. In series ciruity if one bulb fails, the ciruit continuity breaks . In case of paraleel circuit even if one bulb fails the circuit continuity will not get affected
In a parallel circuit, if one light fails, the other lights will continue to work independently because each branch of the circuit is separate and unaffected by the failure of one component. This is in contrast to a series circuit, where the failure of one component would cause all components to stop working.
Adding more lamps in parallel (across) a line will cause total current to climb. It will keep climbing (increasing) until a load protection device (circuit breaker or fuse) breaks the circuit or until something fails because of excessive current.
In a parallel circuit, each component has its own branch and receives the full voltage of the circuit. If one component fails, it does not affect the others. In a series circuit, all components are connected in a line and share the same current. If one component fails, it can disrupt the flow of current to the others.