The induction motor rotor has different frequency compared to it's stator. The rotor has slip ( s ) frequency.
slip = ( Synchronous speed - rotor speed ) / Synchronous speed
Synchronous speed = ( 120 * f ) / P
where f = supply frequency to the stator.
p = no of poles
rotor speed is the actual speed the motor is running.
Frequency in the rotor = slip * frequency in the stator
At starting rotor speed is zero, so slip is one.
Let us take the supply frequency is 50 Hz, then rotor frequency is also 50 Hz at starting.
The motor attains speed and runs with its full speed at a point of time.
Then let us take the slip is 0.04
then the rotor frequency will be 2 Hz.
Standard induction motor has a closed squirrel cage rotor, where as open ended induction motor has split phase rotor.
An induction motor relies on low-frequency currents induced in the rotor by the difference in speed between the rotor and the rotating magnetic field. At sychronous speed the induced current is zero therefore the torque is also zero.
Induction motor is an AC electric motor which uses electromagnetic induction to induce the electric current in the rotor to produce torque.
An induction motor has no excitation, so the question is about a synchronous motor. The rotor speed is determined by the supply frequency. For a given supply frequency and mechanical load, the excitation current can be adjusted to give the best power factor.
short the rotor terminals.
A high frequency induction motor uses high frequency electrical currents to create a rotating magnetic field in the stator. This rotating field induces currents in the rotor, which causes it to rotate and drive the motor. The higher frequency allows for more precise speed control and efficiency in certain applications.
Standard induction motor has a closed squirrel cage rotor, where as open ended induction motor has split phase rotor.
An induction motor relies on low-frequency currents induced in the rotor by the difference in speed between the rotor and the rotating magnetic field. At sychronous speed the induced current is zero therefore the torque is also zero.
Induction motor is an AC electric motor which uses electromagnetic induction to induce the electric current in the rotor to produce torque.
An induction motor has no excitation, so the question is about a synchronous motor. The rotor speed is determined by the supply frequency. For a given supply frequency and mechanical load, the excitation current can be adjusted to give the best power factor.
explain wound rotor
if the motor is at synchronous frequency there is no current induced in the shorted windings in the rotor so at no load its slightly less. if you drive the motor faster than synchronous speed it becomes a generator
short the rotor terminals.
rotor speed = 0
Yes, the induction motor has a rotor winding. It is usually one turn, shorted. This is how the magnetic fields generated in the stator induce a current in the rotor, which subsequently generates a torque from the opposing magnetic fields, stator to rotor.
An induction motor is an alternating current (only) motor that has one or more coils of wire wound on a metal frame that induces a current in the conductors in the rotor when the rotor is moving at a different than synchronous speed. Synchronous speed it determined by the line frequency and the number of poles the motor has. For example, a two pole motor with a 60 Hz line frequency would have a synchronous speed of 3600 RPM. When used with single phase, the magnetic field generated in the stator needs to be caused to rotate around the rotor. In most cases this is initiated by a separate starting winding that is fed out of phase with the running winding(s). Once the rotor is rotating, the stator's field rotation has been established and the starting circuit is generally switched off.
its impossible to give suppy to rotor of an induction motor,because of it a closed path for circulating currents.