A fan unit which has a timer in it must have two separate "hot" wires feeding it:
Depending on the actual design of the control circuitry inside the fan unit, if the above two "hots" have been connected to the fan unit the wrong way round, the result can be that the fan will "stay on and running" all the time, regardless of the position of the on/off switch for its circuit.
The solution is to switch off all the power at the main breaker panel and, after you have checked that no wires are still "hot" or "live", re-wire the "hots" on the fan unit the other way round:
More details:
If the fan stays on after it has been switched off there is probably a timer inside the fan unit which will turn the fan off after a set time. If the fan does not go off after 2 hours from switching it off then either the fan unit has no timer but has been wired up incorrectly - so that it is not controlled by the on/off switch (see above) or the timer may have been set to stay on continuously.
Sometimes a fan may come on when the switch for a light in the same room has been turned on but, if the fan has a timer, that timer will keep the fan running even after the light has been switched off.
Sometimes a fan may have its own on/off switch, separate to another switch controlling a light in the same room. In that situation you might switch off both the light and the fan but, if the fan has a timer, the timer will still keep the fan running even after the light has been switched off.
<><><>
As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.
Before you do any work yourself,
on electrical circuits, equipment or appliances,
always use a test meter to ensure the circuit is, in fact, de-energized.
IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOB
SAFELY AND COMPETENTLY
REFER THIS WORK TO QUALIFIED PROFESSIONALS.
An inside pipe wrench also called a pipe extractor. It drives into the broken off pipe and is then turned with a crescent wrench.Normally a extractor or inside pipe wrench does not work removing a pipe . What works best is the use of a hack saw blade and a chisel to cave in the threads after the threads are cut.. BECAREFUL not to cut into the fitting threads
It doesn't but you better run sir/madam their may be a ghost in your bathroom.
To ohm out a limit switch, first ensure the power is turned off to avoid electrical shock. Use a multimeter set to the resistance (ohms) setting and connect the probes to the terminals of the switch. Activate the switch by pressing it (if it's a normally open switch) or releasing it (if it's normally closed), and observe the multimeter reading: a low resistance (close to 0 ohms) indicates the switch is closed, while a high resistance (infinite or near infinite) indicates it is open. If the readings are not as expected, the switch may be faulty and should be replaced.
To test a water well pressure switch, first ensure the power supply is turned off for safety. Then, use a multimeter to check the continuity of the switch contacts by measuring resistance across the terminals while manually activating the switch. Additionally, observe the pressure gauge to ensure it reflects the pressure settings of the switch, typically around 30-50 psi for a standard system. If the switch fails to activate or shows inconsistent readings, it may need replacement.
To connect a bell to a circuit, first ensure that the power source is turned off for safety. Connect one terminal of the bell to the positive terminal of the power source and the other terminal to a switch. Then, connect the other side of the switch back to the negative terminal of the power source, completing the circuit. When the switch is closed, it allows current to flow, activating the bell.
The purpose of a bathroom fan switch is to control the ventilation system in a bathroom. When the switch is turned on, it activates the fan to remove moisture, odors, and pollutants from the air. This helps to improve air quality and prevent mold and mildew growth in the bathroom.
A water faucet is the mechanical device fitted to the water supply pipes over bathroom and kitchen sinks. When turned on they supply water.
The purpose of the bathroom exhaust fan switch is to control the ventilation system by turning the exhaust fan on and off. When the switch is turned on, it activates the exhaust fan, which helps remove moisture, odors, and pollutants from the bathroom. This helps improve air quality and prevent mold and mildew growth.
A screw extractor is a tool with a reverse-threaded end designed to grip onto a damaged or stripped screw. By drilling a small hole into the screw, the extractor can be inserted and turned counterclockwise to remove the screw from the material. The reverse-threaded design helps to create a gripping force that loosens the screw as it is turned.
If you have any condition in your bathroom where a switch is malfunctioning you need to replace the switch or the device that is causing the problem. This is very dangerous in a bathroom because of the increased danger of shock because of moisture.
ocd
In North America the switch can be placed either inside the room or outside the room. When it is inside the room it is placed on the opening side of the door so that when you enter the room, the switch can be flipped on. When the switch is located on the outside of the room a convenient placement is close to the door opening so that when you open the door the switch can be turned on in one continuous motion.
An electric field causes electrons to flow when a switch is turned on.
An electric field causes electrons to flow when a switch is turned on.
An electric field causes electrons to flow when a switch is turned on.
Current flows through a wire when a light switch is turned on.
A light switch can get hot when turned on because of the flow of electricity through the switch. This flow of electricity causes resistance in the switch, which generates heat as a byproduct.