The only time that there will be zero current flow on the neutral is when the panel is completely balanced on both legs. When you state that the "tester is put on the neutral wire" suggest that the wrong kind of meter or meter scale is being used to test for current. The amperage testing of conductors is done by inserting a meter in series with the conductor or a meter has to be clamped over the wire to measure its magnetic flux of the current going through the wire. If you have mistakenly used a voltage meter to do the test, you will have a zero potential because the neutral and ground wire are bonded together and will have no reading between each other. The same will occur if you are trying to use probes and read off of the amps scale. The probes have to be in series with the circuit to get a reading.

User Avatar

Wiki User

13y ago

What else can I help you with?

Continue Learning about Engineering

How much current carrying in neutral?

In the US , for example, the live wire changes from zero to +120 volts rms, then back to zero, then to -120 volts rms, then back to zero. It goes through that cycle 60 times every second. At all times throughout each cycle, the live wire "feeds" the current at the varying voltage and the neutral wire "returns" it to the power source.A neutral wire is always needed as the return path back to the power station for any single-phase circuit in which a single live wire feeds alternating current into the connected load.As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.Before you do any work yourself,on electrical circuits, equipment or appliances,always use a test meter to ensure the circuit is, in fact, de-energized.IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.


Why is residential wiring called single phase if there are 2 phases coming in?

residential wiring are called single phase because the 2 phases coming in are one is neutral and the other is line.the neutral has a potential zero with ground and it is to provide a closed path for the current to flow through..the line is having a potential of 230V with the ground and a line together with a neutral is called a phase


How three phase line current convert in single phase?

The current is the same in the three live wires. The voltage can be described as the line voltage (phase to neutral) or the phase voltage (phase to phase) which is larger by a factor of sqrt(3). So a line voltage of 230 v corresponds to a phase voltage of 400 v.


Is a neutral considered a current carrying conductor?

No, in a three phase balance load, there should not be any current through Neutral conductor. If it is a 2 wire, single phase system, the Neutral will carry the same current as live conductor if the system has no Earth fault, leak.


Why cant take connection from phase line to neutral line?

A connection can be taken between phase lines, or between one phase and neutral. Both methods give a single-phase supply. Between phases the voltage is sqrt(3) times more than between one phase and neutral. In each case the load gives an unbalanced current on the 3-phase system but the idea is to average out the unbalances over a group of single-phase loads.

Related Questions

Where does the neutral wire go on a single pole switch?

Unless the switch has a light to indicate the switch is turned on, there is no neutral connection to a single pole switch.


What is the limit or range of the neutral current in an unbalanced three phase system for it to be regarded as faulty?

The limit or range of the neutral current in an unbalanced three phase system is the third harmonic in single phase non-linear load current is the major contributor to neutral current.


Is there any current flow through the neutral wire of single phase motor?

Yes. It is identical to the line current.


What is the function of neutralization?

A CT is a current transformer, used to measure current flow in a conductor. Neutral is power return, usually grounded at the distribution panel. A neutral CT, then, is a device that measures the current flow in the neutral conductor. In a three phase star system, each phase returns current to neutral, but the three phases cancel each other out, resulting in effectively zero current in neutral. The neutral CT is used to detect an imbalance in the system, perhaps caused by a ground fault or by some failure in one of the phase loads. In a single phase, single ended system, there is current on neutral, so the value of a neutral CT is not so great. If you also had a hot CT, you could compare and detect imbalance between hot and neutral, which would be an indication of a ground fault. (Actually, a ground fault current interrupting device, also called a GFCI, usually compares current in hot and neutral simultaneously, because both conductors are wound together as the sensing transformer primary - any perceived current is a ground fault.) In a single phase, double ended system, such as the 120/240 split phase system used in the US, a current CT could indicate ground fault or a system imbalance but, usually, imbalance might be a normal situation as various loads are turned on and off.


What is the function of neutral CT?

A CT is a current transformer, used to measure current flow in a conductor. Neutral is power return, usually grounded at the distribution panel. A neutral CT, then, is a device that measures the current flow in the neutral conductor. In a three phase star system, each phase returns current to neutral, but the three phases cancel each other out, resulting in effectively zero current in neutral. The neutral CT is used to detect an imbalance in the system, perhaps caused by a ground fault or by some failure in one of the phase loads. In a single phase, single ended system, there is current on neutral, so the value of a neutral CT is not so great. If you also had a hot CT, you could compare and detect imbalance between hot and neutral, which would be an indication of a ground fault. (Actually, a ground fault current interrupting device, also called a GFCI, usually compares current in hot and neutral simultaneously, because both conductors are wound together as the sensing transformer primary - any perceived current is a ground fault.) In a single phase, double ended system, such as the 120/240 split phase system used in the US, a current CT could indicate ground fault or a system imbalance but, usually, imbalance might be a normal situation as various loads are turned on and off.


What function does the neutral serve when the supply is single phase in a wye connection?

In a single-phase circuit like a house fed from 4-wire three phase in the street, the current flows in the live and neutral wires. The neutral currents from a street of houses are expected to cancel each other so that the overall current in the neutral leaving the transformer is small.


Should individuals indicate their marital status as single or divorced on forms that require this information"?

Individuals should indicate their current marital status, whether single or divorced, on forms that require this information.


Should I indicate my marital status as single or divorced on my tax return?

You should indicate your current marital status on your tax return. If you are legally divorced as of the end of the tax year, you should indicate your status as divorced. If you are not legally divorced by the end of the tax year, you should indicate your status as single.


Why the neutral cable takes high current than the phase lines in three phase installation?

In a balanced three-phase system, the current in the neutral wire should ideally be minimal as the three phase conductors carry equal and opposite currents that cancel out in the neutral wire. However, if the loads are unbalanced, the neutral wire may have higher current due to the uneven distribution of power among the phases. This can happen when loads on each phase are different or when single-phase loads are connected between a phase and neutral, leading to increased neutral current.


In science what is neutral?

Neutral-not moving;on a single position


If the loads were only 240v on a single phase 240v system with a center tapped transformer the neutral conductor would carry?

If the loads are balanced, the neutral conductor in a single-phase 240V system with a center-tapped transformer would carry no current, as the currents flowing in opposite directions would cancel each other out. If the loads are unbalanced, the neutral conductor would carry the difference in currents between the two lines.


Is the neutral conductor a live wire?

YES. ACTUALLY THE SIZE OF NEUTRAL BUSBAR IS BIGGER THAN THE PHASE CURRENT IF ALL THE LOADS IN A 3 PHASE PANELBOARD ARE ALL SINGLE PHASE. In single-phase, which is found in homes, when an appliance is operating, the amps (current) will be equal in the "hot leg" and the neutral. So current IS passing through the neutral wire. In 3-Phase, which is found in a lot of commersial and industrial buildings (including schools), very little current will exist in the neutral IF the current load is BALANCED EQUALLY between the 3 phases. At any given time, however, it is almost impossible to balance the current exactly. So current, even a small amount, will probably exist in the neutral wire. Most certainly enough to harm or kill you! Be it at home, or at work, when the lamp at your desk or by your bed is on, current is flowing through BOTH of the lamp wires!