It is used but not after wavelengths higher than 15 micrometres.

User Avatar

Wiki User

11y ago

What else can I help you with?

Related Questions

What is the source of FTIR instrument?

A Fourier-transform infrared (FTIR) spectrometer is the instrument used to perform FTIR spectroscopy. It works by measuring the absorption of infrared radiation by a sample. It consists of an interferometer and a detector to measure the signal.


What does "FT" stand for in regard to FTIR spectroscopy?

"FT" stands for Fourier Transform in FTIR spectroscopy.


Why lasserbeam uses in ftir?

Lasers are used in FTIR spectroscopy to provide a monochromatic and intense light source, improving spectral resolution and sensitivity. This enhances the ability to detect specific functional groups and chemical bonds in the sample. Additionally, lasers offer stability and coherence, which are essential for precise measurements in FTIR analysis.


Thermo fisher scientific model ftir nicolet 6700?

this is an equipment used to perform DRIFT analyses


What are the key differences between Raman and FTIR spectroscopy techniques?

Raman spectroscopy measures the scattering of light, while FTIR spectroscopy measures the absorption of infrared light. Raman spectroscopy is better for analyzing crystalline materials, while FTIR is more suitable for identifying functional groups in organic compounds. Additionally, Raman spectroscopy is less sensitive to water interference compared to FTIR spectroscopy.


Is the solubility of NaCl affected by the solvent used?

Yes, the solubility of NaCl can be affected by the solvent used. Different solvents can have varying effects on the solubility of a substance like NaCl.


Why use KBr in FTIR?

Potassium bromide (KBr) is used in FTIR spectroscopy as a sample preparation technique to create solid discs containing a small amount of the sample being analyzed. KBr is transparent in the infrared region and can easily be mixed with the sample material to form a uniform and stable mixture, ensuring accurate and reproducible results during FTIR analysis. Additionally, KBr has a low background signal in the IR spectrum, making it ideal for creating transparent and stable sample discs for FTIR measurements.


What is interferometer in FTIR?

An interferometer in FTIR (Fourier-transform infrared spectroscopy) is a device that splits and recombines a beam of infrared light, leading to the generation of an interferogram. This interferogram is then mathematically transformed into a spectrum, providing information about the sample's chemical composition. The interferometer is a crucial component in FTIR spectrometers for producing high-quality spectra.


Range resolution of FTIR?

I always use 400 - 4000cm-1.


What is na used for?

NaCl or table salt


How do you crush a ceramic capacitor for FTIR analysis?

Crushing a ceramic capacitor for FTIR analysis can be done by placing the capacitor in a mortar and pestle and grinding it into a fine powder. Ensure that the ceramic material is completely broken down to achieve a homogeneous sample for FTIR analysis. Wear appropriate protective gear to prevent inhalation of particles during the crushing process.


Damage of RNA by NaCl?

NaCl will not harm RNA. In fact, it is sometimes used as an elution buffer for RNA-Urea gels.