LIFE SAFETY WARNING! [disclaimer] Electricity is dangerous! You can be injured or killed! Improper installations can cause fire, injury and death! The H1 and H4 are the primary connection terminals on a transformer and the X1 and X4 are the secondary connection terminals. This transformer is a dual voltage primary and a dual voltage secondary. Full terminals will be H1,H3,H2,H4 and X1,X3,X2,X4. Jumpers between H3 and H2 for high voltage primary, jumpers between X3 and X2 for high voltage secondary. For low voltage primary, jumpers across H1 and H3 and H2 and H4. For low voltage secondary, jumpers across X1 and X3 and X2 and X4. See related links for connections. National Electrical Code definition, NFPA 70 2005 Article 100 I: Qualified Person. "One who has skills and knowledge related to the construction and operation of the electrical equipment and installations and has received safety training on the hazards involved." <><><> This is not an amateur level project. Call a professional electrician. <><><>
As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed. Before you do any work yourself,
on electrical circuits, equipment or appliances,
always use a test meter to ensure the circuit is, in fact, de-energized.
IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOB
SAFELY AND COMPETENTLY
REFER THIS WORK TO QUALIFIED PROFESSIONALS.
1999 Mitsubishi Mirage Car Stereo Wire DiagramCar Radio Battery Constant 12v+ Wire: Red/BlackCar Radio Accessory Switched 12v+ Wire: BlueCar Radio Ground Wire: ChassisCar Radio Illumination Wire: Green/WhiteCar Stereo Dimmer Wire: Black/YellowLeft Front Speaker Positive Wire (+): Red/WhiteLeft Front Speaker Negative Wire (-): Red/BlueRight Front Speaker Positive Wire (+): RedRight Front Speaker Negative Wire (-): BlueLeft Rear Speaker Positive Wire (+): Yellow/BrownLeft Rear Speaker Negative Wire (-): Yellow/RedRight Rear Speaker Positive Wire (+): Light GreenRight Rear Speaker Negative Wire (-): Yellow/Green
The Kansas barbed wire museum has over 2000 different types of barbed wire on display and barbed wire collecting is a popular hobby.
who invented electric wire
Barbed Wire Soul was created in 1997.
Bouquet of Barbed Wire was created in 1976.
To wire a buck-boost transformer from 208V to 240V, connect the 208V input leads to the appropriate taps on the transformer to step up the voltage. The output leads on the transformer will then provide 240V. Be sure to consult the transformer's wiring diagram and follow all safety guidelines during installation.
To wire a 15 kW dry type transformer for a 240V to 480V configuration, first ensure that the transformer is rated for this voltage conversion. Connect the primary side to the 240V supply by connecting each of the two primary terminals to the respective phases of the 240V supply. For the secondary side, connect the output terminals to the load requiring 480V, ensuring that the load is compatible with the transformer rating. Always follow local electrical codes and safety standards, and consider consulting a licensed electrician for installation.
Yes, first find out how many volts you need on the output. For example, I'll go with 240V for a step up transformer. You would want to put some 10-14 guage wire on the secondary of the transformer, at around 240-250 turns on the transformer. If you can fit thicker wire, then it'll handle more current, but it may blow a fuse once you get such a big transformer.
The recommended wire size for a 240V electrical circuit is typically 10-gauge wire.
The recommended wire size for a 240V 30 amp circuit is typically 10 gauge wire.
The recommended wire size for a 30 amp 240v circuit is typically 10 gauge wire.
The appropriate wire size for a 240V 30 amp circuit is typically 10 gauge wire.
The recommended wire size for a 240V 50 amp circuit is typically 6 AWG copper wire.
The appropriate wire size for a 240V 50 amp circuit is typically 6 AWG copper wire.
The appropriate wire size for a 50 amp 240v circuit is typically 6 AWG copper wire.
The wire size you are looking for is #1 copper with an insulation factor of 90 degrees C. This wire is rated at 140 amp but with a voltage drop correction it will give you 100 amps at the load. The wire for transformer feeders at 125% is included in the sizing.Before you do any work yourself,on electrical circuits, equipment or appliances,always use a test meter to ensure the circuit is, in fact, de-energizedIF YOU ARE NOT REALLY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.
In North America it takes two "hot" wires to obtain 240 volts.