The maximum amperage rating for a standard 15 amp duplex receptacle is 15 amps.
The long slot on a duplex receptacle is the neutral pin.
If it is a duplex receptacle then two cords is the maximum that should be connected to it.
2-3/4"
The types of wire you can use on duplex receptacle with pressure terminal are labeled on the receptacle, next to the holes. AWG 14 and AWG 12 are the typical wire gauges used in this application.
Answer for USA, Canada and countries running a 60 Hertz supply service.Yes, if it is connected with a three wire circuit such as kitchen counter receptacles. In this case both top and bottom of the duplex receptacle are dedicated circuits. An example of a duplex receptacle being the only device in the circuit from a 15 amp breaker is the receptacle for a microwave oven.
In North America the symbol used for a receptacle is a circle with two parallel lines drawn through it. The two parallel lines are started out side of the top of the circle and drawn down to the bottom of the circle and stopped at the outside of the circle.
A duplex receptacle has two devices in a composite assembly on one yoke. It is the receptacle that is what you commonly think of as a receptacle [two places to plug in a lamp...] rather than a single receptacle, which has a place to connect one device. Removing the connecting bar as described in earlier answer merely allows two circuits or separate control of the two devices. original answer: a duplex receptacle is a normal looking receptacle but the little piece of copper bar between the terminal screws on the power side has been broken off and two different circuits feed the two screws- WRONG!
If you are talking about a typical 4"x4" box, you can use a pair of combination dual switches (they have the same shape as a standard receptacle, so you could use a plate made for a double duplex receptacle...see for the type of switch I had in mind) .
The strap or yoke on a duplex grounding type receptacle is the metal component that connects the two outlets together. It serves as the common connection point for the ground wires in the receptacle to ensure proper grounding.
In North America on a 120/240 volt home electrical system, the ground pin on a duplex wall receptacle is on the bottom.
it depend upon the load connected to that power point,and also it belongs what kind of vlot it is 230v or 415vAnswerIf you are referring to wall sockets, then it depends on the electrical regulations for the country in which you live. For example, in the UK the maximum current is 13 A. In North America, the total current per duplex receptacle is 15 A although, in kitchens for example, the two outlets that make up the duplex receptacle can be separated (by separating links at the back), and each separately wired to provide 15 A per outlet.
A parallel duplex receptacle is a type of electrical outlet with two separate plug openings, allowing two devices to be plugged in side by side. This type of outlet is commonly used in homes and commercial buildings to provide multiple power sources in a single location.