answersLogoWhite

0

The Biochemical Oxygen Demand (BOD) test has several limitations, including its time-consuming nature, typically requiring five days for results, which may not reflect real-time water quality changes. It also primarily measures biodegradable organic matter, potentially overlooking non-biodegradable pollutants and toxic substances that can affect aquatic life. Additionally, BOD can be influenced by environmental factors such as temperature and pH, leading to variability in results. Lastly, the test may not accurately represent the oxygen demand in specific conditions, such as in highly polluted waters or during algal blooms.

User Avatar

AnswerBot

1mo ago

What else can I help you with?

Related Questions

Factor may affect BOD test?

The factors that may affect BOD test include: 1. The temperature at which the test is performed. 2. The amount of seeding done


What is the duration in days for BOD test for water analysis at 20 degree c?

It is usually of five days but it may either be 3 days depending upon the the BOD test.


What advantages and disadvantages of the COD test compared to the BOD test?

jamil jubo tahik letum


Why you use blank for the BOD test?

In the BOD (Biochemical Oxygen Demand) test, a blank is used to account for any oxygen demand exerted by materials other than the sample itself, such as the reagents and the dilution water. This ensures that the measured BOD reflects only the oxygen consumed by the biodegradable organic matter present in the sample. By subtracting the BOD of the blank from the sample's BOD, the results provide a more accurate assessment of the sample's organic pollution load.


What are the limitations of benzidine test?

The benzidine test is a test for cyanide. The limitations of this test are that benzidine has been linked to bladder and pancreatic cancer.


How to calculate BOD value in a sample?

if unseeded, BOD = (D1-D2)/Pif seeded, BOD = ((D1-D2)-(B1-B2)f)/PD1 = DO of diluted seeded wastewaterD2 = DO of wastewater after incubationB1 = DO of diluted seed sampleB2 = DO of seed sample after incubationf = ratio of seed volume in seeded wastewater test to seed volume in BOD test on seedP = decimal fraction of wastewater sample used. (vol. of wastewater)/(vol. of dilution water plus wastewater)Maybe that helps


What are the main sources of error in a BOD test?

The main sources of error in a BOD test include incomplete sample mixing, temperature fluctuations affecting microbial activity, inconsistent incubation times, and microbial growth from outside contamination.


Why cod is greater than bod?

COD measures the amount of oxygen required to chemically oxidize (break down) organic and inorganic matter in a water sample, while BOD measures the amount of oxygen consumed by microorganisms during a biological process that breaks down organic matter. COD typically gives a higher value than BOD because it includes both the chemical and biological oxygen demand in the water sample.


Role of nitrifying bacteria in BOD test?

IN BOD test, Nitrifying bacteria do nitrification which is the process of biological conversion of ammonia into nitrate. Nitrifying bacteria does nitrification because that's the only reason they are termed as nitrifying bacteria otherwise they would be named as something else like if they would do esterification, they would be termed as esterifying bacteria


What is BOD and COD of spent wash?

COD=100 What is Bod


When was Bod - series - created?

Bod - series - was created in 1975.


When did Bod - series - end?

Bod - series - ended in 1984.