A heat exchanger with straight tubes in a shell that can normally be mechanically cleaned
ac condenser means "Air Cooled Condenser". The cooling media is Air. The fluid or anything which is being circulated through (inside) the coils /tube being cooled by the exposed or forced air - which impinges over the outside of the coil / tubes. B.Kannan balakannan@live.com
The hydro-testing procedure of a shell and tube heat exchanger requires you to fill the shell and tubing with water that had a color dye added to it. Then, raise the internal pressure by 1.5 times the operating pressure suggested by the manufacturer. If there are any cracks in the vessel, the water will be forced out through the cracks.
It's the flat, flanged cover on the front (and sometimes the rear) of a shell & tube heat exchanger.
condenser capacity(kw) = compressor cooling capacity (kw) + compressor input (kw) power condenser capacity(kw) = Pf + Pa
An air condenser takes in the surrounding air(at about 45-50 degree Celsius). The vapor at high pressure enters the condenser and accepts the latent heat of condensation from the hot airthereby rejecting heat to condensing coils. The vapor then becomes liquid.
When both the tube side and shell side fluids are fouling, a double-pipe or shell-and-tube condenser is generally preferred. Shell-and-tube condensers offer greater flexibility for cleaning and maintenance, as the design allows for easy access to both the shell and tube sides. Additionally, they can be designed with multiple passes, which enhances heat transfer efficiency and accommodates fouling. This adaptability makes them a better choice for applications facing fouling on both sides.
The bundle factor in a shell and tube condenser refers to the effectiveness of the tube bundle in promoting heat transfer between the fluids. It is defined as the ratio of the actual heat transfer area provided by the tube bundle to the theoretical heat transfer area if all tubes were completely utilized. A higher bundle factor indicates better use of the available tube area, resulting in improved thermal performance and efficiency of the condenser. This factor is crucial for optimizing design and operational parameters in heat exchangers.
Water vapor condenses in a cold condenser tube.
A tube light uses a condenser which is the old term for a capacitor. It functions as a small battery in a circuit.
Importance to keep inner tubes of condenser cold
where is the ac condenser drain tube on a 2008 Saturn Outlook.
Importance to keep inner tubes of condenser cold
Its in the outlet of the condenser.
It is located in the liquid(lower) line at the condenser. This line runs from condenser to accumilator.
It is in the condenser at the connection to the liquid line. This is the line that comes up from the bottom of the condenser.
Most GM's put the orfice tube in the output side of the condenser, near the bottom. Locate the fitting that runs from the condenser to the firewall, open that fitting and the orfice tube should be inside.
It is located in the inlet tube of the evaporator between the outlet of the condenser and the inlet of the evaporator. This point can be found in a properly functioning system by locating the area between the outlet of the condenser and the inlet of the evaporator that suddenly makes the change from hot to cold. You can see small dimples placed in the line that keep the orifice tube from moving inside the tube. It is located just a few inches outside of the condenser in the tube.