Best Answer

Only use calibration control in unloaded condition of the torque transducer. Cal control output is approximately equal to transducer full scale output. Exact value is noted on calibration certificate.

User Avatar

Wiki User

11y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What is shunt calibration?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Mechanical Engineering

What is the calibration curve of orifice meter?

The calibration curve for an orifice meter will depend on the size of the orifice, the size of the pipe and the pressure loss over the meter. Typical calibration curves have pressure (or head) loss on the vertical (y) axis and flow rate on the horizontal (x) axis.


How do you calibrate a dumpy level?

AIM/PURPOSE: To describe the instruction for the calibration of Dumpy Level to ensure that equipment is maintained in fully serviceable condition, is safe to operate and meets environmental requirements. FOR THE CALIBRATION OF DUMPY LEVEL The method described below is to be used on-site check prior to use as to the accuracy of the Dumpy level between calibration checks. This Work instruction shall be conducted at the commencement and completion of a contract. 1. Drive two pegs, "A" & "B", into the ground six metres or more apart 2. Set Dumpy up at "C" 3. Shoot a level at "A" and "B" 4. Relocate Dumpy to "D" and shoot a level at "A" and "B" 5. Record the appropriate result in the workbook. (Levels shot at "D" should be within ± 10mm of "C") D A C B


What is the function of a feeler gauge?

The important point in feer gauges ( also called thickness gages by some of the manufacturers ) is the thickness of the blades. Therefore in order to calibrate a feeler gauge you need to measure the thickness of the gauge at various locations along the length of the device. The standard used in the calibration should satisfy a TUR ( Test Uncertainty Ratio ) of at least 4:1 in order to limit the FAR ( False Accept Risk ) to nearly 2%. Such devices do not require periodic calibration. However, they should be standardized before every use by a standard in order to assure reliable measurements.


Where should tools and equipment should be stored and located?

in the cupboard with Michael Jackson


How is motor operated valve calibrated?

Usually with electronically controlled valves or any other device that has movement limits, there will be either a slotted ribbon, or 2 sensors and a stepper motor where the device can auto calibrate by moving until both sensors are hit, then it can calibrate it's self and move to a predetermined home position. The same is with a ribbon, (a good example of that design is a printer where you will see it spin the feed wheels and move the heads from side to side on startup to calibrate it's self) Usually electronically controlled valves do not need any user adjustment for calibration. (at least with heating and cooling systems)

Related questions

What are the differences of Long shunt vs short shunt generator?

In long shunt the shunt field winding is in parallel to both generator and series field. In short shunt the shunt field is in parallel to generator only.


How do you use shunt in a sentence?

The word 'shunt' is both a noun (shunt, shunts) and a verb (shunt, shunts, shunting, shunted).Examples:He had to have a heart shunt put in. (noun)The engineer will shunt the train onto that track instead. (verb)


Calibration of gas chromatography?

What is the precedure for calibration of gas chromatography? How calibration is perform for gas chromatography? What is the precedure for calibration of gas chromatography? How calibration is perform for gas chromatography?


What is a ventriculoperitoneal shunt?

When a shunt drains to the abdomen


1.physiological shunt?

physiological shunt.


What is advantages of Aryton Shunt?

What is advantages of Aryton Shunt??


Is vp shunt safe in 1.5t mri?

Yes it is perfectly safe up to 1.5T This is an entirely inadequate answer! There are several shunt valves that are magnetically activated and need to be re-calibrated immediately after a MRI. The shunt and valve need to be positively identified before a the scan and then the specific manufacturers recommendations in regards to scan parameters and re-calibration must be followed. MRI Safety.com is a good resource to check these things out. I have been a MRI Technologist for many years and have seen this issue come up many times.


What is called when a child has value shunt caused of water in the brain?

The shunt used for a person who has hydrocephalus ("water on the brain") is not called a "value shunt". It is usually called a "ventriculo-peritoneal shunt" or "VP shunt" for short. Sometimes a "ventriculo-atrial shunt" or "VA shunt" is used instead.


Is shunt a Medical Term?

Yes, shunt CAN be a medical term.


What are the side effects of a VP shunt?

smoking with a vp shunt


What does a ventricular shunt relieve?

A ventricular shunt relieves hydrocephalus


Is VP shunt adjustable?

Yes, a VP shunt is adjustable.