avoid thrust
to mitigate the axial thrust.
Due to pascals law
A recirculation line in a boiler feed pump is used to return part of the pumped water back to the inlet of the pump. This helps to prevent cavitation and maintain a steady flow of water through the pump. Cavitation is a phenomenon that can occur in pumps when the pressure of the water being pumped drops below the vapor pressure of the water. When this happens, bubbles of vapor can form in the pump, which can cause damage to the pump and reduce its efficiency. The recirculation line helps to prevent cavitation by returning part of the water that has been pumped back to the inlet of the pump. This increases the pressure of the water at the inlet, which helps to prevent the formation of vapor bubbles. As a result, the pump can operate more efficiently and reliably. Overall, the use of a recirculation line in a boiler feed pump helps to prevent cavitation and maintain a steady flow of water through the pump. This can improve the performance and reliability of the pump.
Higher torque, lower horsepower
Since sufficient feedwater is not supplied into the economizer though the heat is absorbed from flue gas at the boiler start-up and low load operation, steaming may occur in the economizer. Therefore the economizer recirculation line is provided between the furnace downcomer and the economizer inlet feedwater piping. This line provides the recirculation flow between the drum, the downcomer and the economizer so as to prevent steaming in the economizer. Economizer recirculation valve is only opened at initial stage of the boiler start-up.
Boiler feed pump's suction pressure be aprox. 15Kg/cm2 and discharge pressure be 180Kg/cm2. So the balancing line balance the pressure and protect the boiler feed pump. my quastion is that what is the working principal of balancing leak off
In boiler feed water line the NRV is normally installed between Pump and stop valve if the line is short and an another NRV is installed at boiler entrance and after stop valve if the line is long or pump is 10 to 15 m away from the boiler.
The feed check valve of a boiler is on the line coming out of the boiler it is usually to prevent the water from going back in to the boiler its coming out of so it would build up excessive amounts of pressure which will cause the t&p valve to blow temperature and pressure
In boiler feed pumps usually the discharge pressure is 20 to 30 times tie suction Pressure so to protect the pump balancing line is given from discharge to suction.
to mitigate the axial thrust.
Install an oil shock eliminator
its easy if you do this they wont you to make a line for the pipes so they go in a line to the boiler so you can get air into the boiler
waves
A pinhole leak or a valve on the line not shutting off properly and introducing air into the water line feed.
Yes . So far most of the plants use only carbon steel
Stop Boiler Valve (or Crown Valve) is installed on an outlet line of a boiler. It's purpose is isolation of a boiler from a downstream steam line. Its position may be either open or close, it cannot be used for throttling of steam.
The high pressure line is a high pressure hydraulic line. The can leak from the attachments to the fittings. The will leak where the line is damaged Or if it as a very old line they can crack.