Possibly, most 230 volt saws draw about 16-18 amps on each line. There will be a spec plate on or by the motor which has the amp draw marked. CHECK this first.
No, it is not safe to use two 20 amp circuit breakers to protect a 40 amp circuit. Circuit breakers are designed to protect the wiring in a circuit from overheating, and using a higher amperage circuit breaker than the wiring is rated for can lead to overheating and potential fire hazards. It is important to use the correct size circuit breaker for the amperage rating of the circuit.
On a hand crank megger which is used to test insulation breakdown, use the 300V setting. If the megger does not have that setting use 500V as opposed to 1000V for the test. The output of the megger is a DC voltage.
230V/50Hz
A 30 amp circuit breaker is needed unless the load is a motor circuit, then it has to be sized to 250 percent of the motors full load amps. For 30A circuit is needed breaker 30*1.25=37.5 --> 40A. If load is lamp or heater, then use breaker of group A or B. If load is motor, then use breaker of groupC or D (very hard start) or special safe breaker for motor - with variable amp setpoint. See related link also. By code you are only allowed 80% of the rating of a breaker. So 30x80%=24amps. 24 amps is the MAX allowed on a 30 amp breaker. You would need a 40amp breaker for a 30 amp circuit. 40x80%=32. So you would want a double pole 40amp breaker.
Voltage in India is 230V / 50 Hz
To convert 1000W at 24V DC to an equivalent wattage at 230V AC, you can use the formula P = VI, where P is power, V is voltage, and I is current. First, calculate the current at 24V DC using P = VI. Then, use this current with 230V to find the equivalent power at 230V AC.
Actually, electrical current in Poland is 230V.
To use 230V equipment in the US, you will need a step-down voltage converter to convert the standard US voltage of 120V to the required 230V. Make sure to check the wattage and compatibility of the converter with your equipment to avoid any damage. Additionally, ensure that the equipment is compatible with the US electrical system and plug type.
As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed. Before you do any work yourself,on electrical circuits, equipment or appliances,always use a test meter to ensure the circuit is, in fact, de-energized IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.
we can apply 230v ac to kbpc2510 maximum peak voltage is 325v (for 230v) and its blocking capacity is about 1000v so we can use it (I used for the same application)
The formula you are looking for is Amps = Watts divided by Volts. Once you find the amperage you can decide as to the size of a fuse you should use. Remember that fusing protects the conductors of the circuit and not the load of the circuit. A #14 wire is rated at 15 amps and can legally be loaded only to 12 amps.
415V 3 phase is the line to line voltage. The line to neutral of this supply is 230V single phase. Therefore you use one of the phases and the neutral.