Yes provided the voltage is compatible.

User Avatar

Wiki User

14y ago

What else can I help you with?

Continue Learning about Natural Sciences

Can you use a none dedicated outlet for a space heater for a short period of time?

Yes, a space heater can be plugged into any outlet. Depending on what else is drawing current on the circuit will govern whether the circuit will trip or not. If the heater is plugged in and the circuit does not trip it can be left plugged as long as it is needed. If the heater trips after a few seconds, then try another outlet.


What rating of MCB is required for an immersion heater?

An immersion heater typically requires a dedicated circuit with a Miniature Circuit Breaker (MCB) rated at 16A or 20A, depending on the power rating of the heater. It is recommended to consult with a qualified electrician to determine the appropriate MCB rating based on the specific requirements of the immersion heater.


What should a 3 kW immersion heater circuit must be provided with?

A 3 kW immersion heater circuit should be provided with a dedicated 15 Amp circuit that is protected by a 15 Amp circuit breaker and wired with appropriately sized cables (typically 14 AWG for residential wiring in the US). Additionally, a Ground Fault Circuit Interrupter (GFCI) protection may be required for safety.


Can you plug a 1500 watt heater in to a regular apartment outlet?

No, a 1500 watt heater exceeds the typical 120 volt, 15 amp capacity of a regular apartment outlet. It requires a dedicated circuit with a higher amp capacity to safely operate the heater without overloading the circuit and causing a fire hazard.


Suppose that you turn on the heater in your room and all of the lights in your room go out Propose a reason why the lights went out?

One reason could be that the heater was wired into the lighting circuit so that when the heater is turned on its high current draw causes the circuit breaker to "trip" to shut off the current.A lighting circuit is intended to be used only for lights.Further answer for USA, Canada and countries running a 60 Hz supply service.A small electric heater - under 2 kilowatts in power - should only ever be connected into a branch circuit feeding power outlets, providing you have checked that the circuit's existing circuit breaker and cable size are of the appropriate ampacity to be able to take the extra current draw safely.If it is over 2 kilowatts in power it should be connected into its own dedicated circuit using:correct type of circuit breaker unit of the appropriate ampacitycorrectly sized cable and eithercorrect type and size fixed outlet (non-pluggable) orcorrect type and size socket outlet taking an appropriate plug.As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.Before you do any work yourself,on electrical circuits, equipment or appliances,always use a test meter to ensure the circuit is, in fact, de-energized.IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.

Related Questions

How do you get to the bulb for lighting your heater controls?

To get to the bulb for lighting the heater controls, the front panel will have to be removed. Depending on the type of vehicle, the knobs might have to be popped off first. It is also possible on some vehicles to get to the lighting for the heater controls from under the dash.


Can you use a none dedicated outlet for a space heater for a short period of time?

Yes, a space heater can be plugged into any outlet. Depending on what else is drawing current on the circuit will govern whether the circuit will trip or not. If the heater is plugged in and the circuit does not trip it can be left plugged as long as it is needed. If the heater trips after a few seconds, then try another outlet.


What is the wiring and gfci for a bathtab jacuzzi?

Connect incoming power to the line side of GFCI outlet and plug Jacuzzi into the outlet. Must be on a dedicated circuit. If it has a pump and heater then each one must be on dedicated GFCI protected circuit.


What rating of MCB is required for an immersion heater?

An immersion heater typically requires a dedicated circuit with a Miniature Circuit Breaker (MCB) rated at 16A or 20A, depending on the power rating of the heater. It is recommended to consult with a qualified electrician to determine the appropriate MCB rating based on the specific requirements of the immersion heater.


Why does my space heater keep tripping the breaker?

Your space heater may be tripping the breaker because it is drawing too much power and causing an overload on the circuit. This can happen if the heater is plugged into a circuit that is already handling a heavy load or if the heater itself is faulty. It is important to make sure the heater is plugged into a dedicated circuit and not sharing power with other high-wattage devices. If the issue persists, it may be a good idea to have the heater inspected by a professional.


What should a 3 kW immersion heater circuit must be provided with?

A 3 kW immersion heater circuit should be provided with a dedicated 15 Amp circuit that is protected by a 15 Amp circuit breaker and wired with appropriately sized cables (typically 14 AWG for residential wiring in the US). Additionally, a Ground Fault Circuit Interrupter (GFCI) protection may be required for safety.


How do I properly wire a baseboard heater for optimal performance and safety?

To properly wire a baseboard heater for optimal performance and safety, follow these steps: Turn off the power to the circuit where the heater will be installed. Use the correct gauge wire for the heater's voltage and amperage requirements. Connect the wires to the heater according to the manufacturer's instructions. Use wire connectors to secure the connections and prevent them from coming loose. Install a dedicated circuit breaker for the heater to prevent overloading the circuit. Test the heater to ensure it is working properly before use. By following these steps, you can ensure that your baseboard heater is wired correctly for optimal performance and safety.


How do you wire a tankless water heater?

To wire a tankless water heater, you need to connect it to a dedicated circuit with the appropriate voltage and amperage. This typically involves connecting the hot and neutral wires from the circuit to the corresponding terminals on the water heater, as well as grounding the unit for safety. It is important to follow the manufacturer's instructions and local electrical codes when wiring a tankless water heater to ensure proper installation and safe operation.


What is a circuit that feeds a heater called?

Environment Circuit


Can you plug a 1500 watt heater in to a regular apartment outlet?

No, a 1500 watt heater exceeds the typical 120 volt, 15 amp capacity of a regular apartment outlet. It requires a dedicated circuit with a higher amp capacity to safely operate the heater without overloading the circuit and causing a fire hazard.


Heater sensor circuit Chevy Astro 2000?

heater sensor circuit Chevy astro 2000


What are the installation requirements for a 220 baseboard heater?

The installation requirements for a 220 baseboard heater include ensuring proper electrical wiring, a dedicated circuit, appropriate voltage, and sufficient clearance around the heater for safety and efficiency. It is important to follow manufacturer instructions and local building codes when installing a 220 baseboard heater.