answersLogoWhite

0

Yes and no. It can run without a starter, but it can't start. The starter stores energy and releases it all at once, causing a higher voltage. The gas in the tube has a higher resistance when not lit, so it takes more voltage to start it glowing. Once it is glowing, the resistance is lower, so it can run without a starter.

User Avatar

Wiki User

17y ago

What else can I help you with?

Continue Learning about Natural Sciences

Functions of choke and starter in a fluorescent lamp?

The choke is used to limit the current flowing through the fluorescent lamp during start-up, allowing the lamp to warm up gradually. The starter is responsible for providing the initial high-voltage kick needed to start the lamp by ionizing the gas inside the tube. Together, the choke and starter work to regulate the flow of electricity and provide the necessary conditions for the fluorescent lamp to operate efficiently.


What is the difference between a rapid start and a preheat start fluorescent lamp?

A rapid start fluorescent lamp uses a preheat mechanism where the electrodes are heated before the gas is ionized, allowing for a quick start without flickering. In contrast, a preheat start fluorescent lamp requires a separate starter component that momentarily connects the electrodes before the lamp ignites, leading to a slight delay in startup. Rapid start lamps are typically more efficient and provide smoother operation, while preheat lamps can have a longer warm-up time.


Can a single pole switch replace a starter in a fluorescent lamp?

No, a single pole switch cannot replace a starter in a fluorescent lamp. The starter is required to initiate the flow of current through the tube, which a switch alone cannot accomplish. The switch is used for turning the lamp on and off once the starter has activated the lamp.


Can we use fluorescent lamp in dc?

Yes, fluorescent lamps may be powered by DC but they need a DC lamp controller instead of an AC ballast and starter. The DC lamp controller is more complex. I have a 12V lantern with fluorescent lamp tubes.


Can we run the fluorescent light fitting without capacitor?

No, a fluorescent light fitting typically requires a capacitor to function properly. The capacitor helps to regulate the electrical current and improves the efficiency of the light, ensuring stable operation and reducing flickering. Without it, the fluorescent lamp may not start, or it could flicker and have a shorter lifespan.

Related Questions

Functions of choke and starter in a fluorescent lamp?

The choke is used to limit the current flowing through the fluorescent lamp during start-up, allowing the lamp to warm up gradually. The starter is responsible for providing the initial high-voltage kick needed to start the lamp by ionizing the gas inside the tube. Together, the choke and starter work to regulate the flow of electricity and provide the necessary conditions for the fluorescent lamp to operate efficiently.


What would be the effect on the circuit if the starter was taken out after the fluorescent lamp is started?

A; fluorescent lamps needs 500 v to start once started the voltage drops to ~90 v the starter perform the kicking to get to 500 volts without it it will not start so taking it out after it started that is when it is not longer needed


Can a single pole switch replace a starter in a fluorescent lamp?

No, a single pole switch cannot replace a starter in a fluorescent lamp. The starter is required to initiate the flow of current through the tube, which a switch alone cannot accomplish. The switch is used for turning the lamp on and off once the starter has activated the lamp.


What is the necessity of the starter in fluorescent lamp?

When line voltage is applied across the starter, it closes a circuit, connecting the filaments at the ends of the bulb in series so they heat up. Once the Mercury in the lamp is vaporized, the starter breaks the filament circuit, and the ballast provides a voltage pulse to start the current flow down the length of the tube, lighting it. While the bulb is lighted, the voltage across the starter is low and it does not energize the filaments. When you see a fluorescent lamp flashing, the bulb is worn out and the starter keeps vainly trying to start it. Eventually the starter will wear out and will need to be replaced also. Newer fluorescent fixtures have lamps and ballasts that do not require a starter.


What is the necessity of a starter in a fluorescent lamp?

When line voltage is applied across the starter, it closes a circuit, connecting the filaments at the ends of the bulb in series so they heat up. Once the mercury in the lamp is vaporized, the starter breaks the filament circuit, and the ballast provides a voltage pulse to start the current flow down the length of the tube, lighting it. While the bulb is lighted, the voltage across the starter is low and it does not energize the filaments. When you see a fluorescent lamp flashing, the bulb is worn out and the starter keeps vainly trying to start it. Eventually the starter will wear out and will need to be replaced also. Newer fluorescent fixtures have lamps and ballasts that do not require a starter.


What is a starter in a fluorescent tube?

A starter in a fluorescent tube is a small device that helps initiate the lighting process by preheating the electrodes inside the tube. When the fluorescent lamp is turned on, the starter quickly closes the circuit, allowing current to flow through the gas and ignite the lamp. Once the lamp is lit, the starter disengages from the circuit, allowing the lamp to operate normally. Starters are typically used in older fluorescent lighting systems, while newer designs often rely on electronic ballasts that eliminate the need for a starter.


Can we use fluorescent lamp in dc?

Yes, fluorescent lamps may be powered by DC but they need a DC lamp controller instead of an AC ballast and starter. The DC lamp controller is more complex. I have a 12V lantern with fluorescent lamp tubes.


Can we use a fluorescent lamp in DC?

Yes, fluorescent lamps may be powered by DC but they need a DC lamp controller instead of an AC ballast and starter. The DC lamp controller is more complex. I have a 12V lantern with fluorescent lamp tubes.


Is lamp to a fluorescent?

Yes, lamp is to fluorescent


What is the function of glow starter?

A glow starter is used in fluorescent lighting systems to initiate the lighting process. It works by providing a brief spark to ionize the gas within the tube, allowing current to flow and the lamp to illuminate. Once the lamp is lit, the glow starter disconnects from the circuit, enabling the fluorescent lamp to operate efficiently. This component is essential for reliable lamp ignition and helps ensure consistent lighting performance.


Why does fluorescent light come on when starter removed?

Fluorescent lights rely on a starter to help initiate the arc between the electrodes. When the starter is removed, it can cause a change in the electrical circuit, allowing current to flow more freely and potentially enabling the fluorescent lamp to ignite without the starter's assistance. However, this is not a standard or safe operation, as it can lead to inconsistent lighting or damage the fixture. It's important to use fixtures as designed for safe and reliable operation.


What would be the effect on the circuit should the starter be taken out the lamp is started?

Once started the fluorescent tube no longer needs the starter. In fact starters are designed to electrically "remove" themselves from the circuit when the fluorescent tube is conducting.