answersLogoWhite

0

Answer for USA, Canada and countries running a 60 Hz supply service.

Buy a new 4 plug cord for the dryer and hook its ground wire up to the drier and hook red to red, black to black, white to white.

Also make sure you remove the copper bonding strap between the white wire terminal and the dryer metal frame. then connect the white wire to the white wire terminal and the green wire to the frame.

<><><>

As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.

Before you do any work yourself,

on electrical circuits, equipment or appliances,

always use a test meter to ensure the circuit is, in fact, de-energized.

IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOB

SAFELY AND COMPETENTLY

REFER THIS WORK TO QUALIFIED PROFESSIONALS.

User Avatar

Wiki User

14y ago

What else can I help you with?

Continue Learning about Natural Sciences

What is wrong if you changed a four prong to a three prong and the dryer is not heating?

My question is WHY did you replace a four prong dryer plug with a three prong! 220 volt Electric dryers require two hot legs, a neutral and a system ground wire. Sounds as though you shunted one of the hots or the neutral. You need to install a four prong plug of the same configuration and wire it exactly as the original.


How do you change the plug on your clothes dryer cord from three prong to four?

To change the plug on your clothes dryer cord from three prongs to four, you will need to first disconnect the dryer from the power source. Then, remove the old three-prong plug by unscrewing it and replacing it with a new four-prong plug. Make sure to connect the wires to the correct terminals on the new plug following the manufacturer's instructions. It's recommended to consult a professional electrician if you are unsure about the process.


Can you plug a three-prong dryer into a four-prong outlet or is there an adapter you should use?

You should install a four prong. The older ones were three prong and had no ground. An adaptor isn't made because it wouldn't fix the problem. You could make your own adaptor and cut the ground off with a pair of dykes, but don't.


You are trying to change a 3 prong cord to a 4 prong your new dryer has two green cables attached to the inside of the dryer?

Dryer plug three to fourOpen up the electrical access panel on the back of the dryer. You will see a terminal block with three wires going into it from the plug cord assembly. A red and black and white are now connected to the terminal strip. Look at the position and colours of the existing 3 prong cord and how it is connected. Make a diagram. Coloured wires on the outside terminals white in the center. From the center wire terminal you will see a jumper strap that goes to the frame of the dryer. When installing the four prong plug this jumper is removed completely. The kit should have with it a grounding lug that connects to where the removed grounding strip attached to the frame of the dryer. This is the attachment point for the fourth green ground wire from the new dryer cord assembly.


What if you have four wires running to your dryer outlet and the outlet is only a three prong one wire is just hanging out is this really even safe?

No, it is not safe to have a wire hanging out of an outlet. If you have a four-wire connection but only a three-prong outlet, this could pose a safety hazard. You should have a qualified electrician properly install a matching outlet to avoid any risk of electrical shock or fire.

Related Questions

What is wrong if you changed a four prong to a three prong and the dryer is not heating?

My question is WHY did you replace a four prong dryer plug with a three prong! 220 volt Electric dryers require two hot legs, a neutral and a system ground wire. Sounds as though you shunted one of the hots or the neutral. You need to install a four prong plug of the same configuration and wire it exactly as the original.


How do you change the plug on your clothes dryer cord from three prong to four?

To change the plug on your clothes dryer cord from three prongs to four, you will need to first disconnect the dryer from the power source. Then, remove the old three-prong plug by unscrewing it and replacing it with a new four-prong plug. Make sure to connect the wires to the correct terminals on the new plug following the manufacturer's instructions. It's recommended to consult a professional electrician if you are unsure about the process.


How can I safely convert a dryer from a four-prong to a three-prong plug?

To safely convert a dryer from a four-prong to a three-prong plug, you will need to replace the cord with a three-prong cord that matches the outlet in your home. Make sure to follow the manufacturer's instructions and turn off the power before making any changes. If you are unsure, it is recommended to consult a professional electrician for assistance.


Who sells 8 ft 3 prong dryer cords?

Under the new electrical code rules three prong dryer cord receptacles and therefore cords are not allowed to be installed. As you are finding out, stores are not carrying them in stock any more. You should consider an upgrade for safety sakes, to a four prong plug cord and change the wall receptacle to a four prong receptacle. There are instructions on how to do this your self on Answers.


Can you plug a three-prong dryer into a four-prong outlet or is there an adapter you should use?

You should install a four prong. The older ones were three prong and had no ground. An adaptor isn't made because it wouldn't fix the problem. You could make your own adaptor and cut the ground off with a pair of dykes, but don't.


You are trying to change a 3 prong cord to a 4 prong your new dryer has two green cables attached to the inside of the dryer?

Dryer plug three to fourOpen up the electrical access panel on the back of the dryer. You will see a terminal block with three wires going into it from the plug cord assembly. A red and black and white are now connected to the terminal strip. Look at the position and colours of the existing 3 prong cord and how it is connected. Make a diagram. Coloured wires on the outside terminals white in the center. From the center wire terminal you will see a jumper strap that goes to the frame of the dryer. When installing the four prong plug this jumper is removed completely. The kit should have with it a grounding lug that connects to where the removed grounding strip attached to the frame of the dryer. This is the attachment point for the fourth green ground wire from the new dryer cord assembly.


What if you have four wires running to your dryer outlet and the outlet is only a three prong one wire is just hanging out is this really even safe?

No, it is not safe to have a wire hanging out of an outlet. If you have a four-wire connection but only a three-prong outlet, this could pose a safety hazard. You should have a qualified electrician properly install a matching outlet to avoid any risk of electrical shock or fire.


How do you connect two three prong outlet to four prong transfer switch?

There is not enough information stated as to what you are trying to do.


Are there 3 prong to 4 prong adapters for driers?

No, and adapters are not needed. What needs to be done in remove the old three blade dryer plug and install a new four blade cord on the dryer.Dryer plug three to fourInstructions should come with the new cord. Open up the electrical access panel on the back of the dryer. You will see a terminal block with three wires going into it from the plug cord assembly. A red and black and white are now connected to the terminal strip. Look at the position and colours of the existing 3 prong cord and how it is connected. Make a diagram. Coloured wires on the outside terminals white in the center. From the center wire terminal you will see a jumper strap that goes to the frame of the dryer. When installing the four prong plug this jumper is removed completely. The kit should have with it a grounding lug that connects to where the removed grounding strip attached to the frame of the dryer. This is the attachment point for the fourth green ground wire from the new dryer cord assembly.


What is the most cost efficient and quick way to fix the problem if you have a stove that has a four-prong cord and an outlet that only takes three prongs?

To fix this issue, you can replace the outlet with a four-prong outlet that matches the stove's cord. Alternatively, you can replace the stove's cord with a three-prong cord that fits your current outlet. Both solutions are relatively quick and cost-effective fixes for the mismatched prong configurations.


What is the difference between a 4 prong dryer outlet and a 4 prong stove outlet?

The four blade dryer plug brings a separate ground wire from the machine to the electrical grounding system. The three blade dryer plug depended on the neutral wire of the plug to make this connection.


How do you hook up 4 prong cord to 3 prong dryer?

To adapt a three prong range cord?&aelig;to a four prong outlet you need to remove the screws from the back plate to open the electric access panel. Then, pull out the copper grounding strip attached to the middle terminal. Next, remove the green ground screw from under the terminal block and attach it to the four prong outlet.?&aelig;